52
Pellerin Milnor Corporation
Display or Action
Explanation
Acknowledges that the data transfer is complete and returns to the
Program
menu.
PROGRAM
4
MENU
DATA TRANSFER
Data Transfer
menu display. Scroll to
Program
menu item
0
,
then turn the
Run/Program
keyswitch to the
Run
position.
Scroll the
Program
menu selections.
PROGRAM
0
MENU
OK
TURN KEY TO RUN
From item
0
of the
Program
menu, return to normal operating
mode.
Return to normal operating mode. Press
if necessary to con-
firm that the key is at
Run
.
RUN PROGRAM00 OK TO
POWER OFF
The
Run Program
display appears to indicate that it is safe to
turn the machine off.
Turn off power to the machine(s).
Disconnect the memory storage device, remove the key, and put
both in secure locations. For two machines, remove the connect-
ing cable.
2.3.6.3
Restoring Saved Data to the Machine from the Storage Device
or Another Machine
BNCJUP05.R03 0000195423 C.2 D.2 A.6 1/2/20 1:16 PM Released
Display or Action
Explanation
Turn off power to the machine(s) before connecting the serial
memory storage device.
Connect the storage device to the machine using the 9-pin round
connector. For two machines, use a serial cable constructed as de-
scribed in
5.3: Construction of External Serial Link Cables, page
Apply power to the machine(s). The storage device receives
power through the connector from the power supply in the
machine.
RUN PROGRAM00 OK TO
POWER OFF
When the
Run Program
display appears, switch from
Run
mode
to
Program
mode.
Turn the
Run/Program
keyswitch on the machine controller(s)
from the
Run
position to the
Program
position.
PROGRAM
0
MENU
OK
TURN KEY TO RUN
Controller display when the
Run/Program
keyswitch is set to
(
Program
position).
Scroll down in the
Program
menu to
Data Transfer
.
PROGRAM
4
MENU
DATA TRANSFER
This is the
Data Transfer
menu selection. Follow the procedure
in
Содержание E-P Plus