Pellerin Milnor Corporation
43
pressure tube connection on the drain sump. Because the pressure
tube between the pressure transducer and the cylinder connects at
an elevation not exactly equal to the bottom of the cylinder, this
value allows for an accurate display of the water level. The unit of
this value is tenths of an inch, so a difference of 1.8 inches is en-
tered as 18. The maximum allowable value is 3 inches prior to
software version 97004, and 4.5 inches with software versions
97004 and later.
LEVEL 1 HEIGHT ?
6
This value is the depth of the water measured from the bottom of
the cylinder. This level will be used for any programmed bath step
commanding
Level 1
.
Level 1
must be achieved before steam is
allowed in any bath commanding steam.
The minimum level that can be configured for Level 1 is 5 inches
(13 centimeters) for V_J models. The minimum setting for H_J
models is 4 inches (10 centimeters). See
for recommended water levels.
LEVEL 2 HEIGHT ?
8
This value is the depth of the water measured from the bottom of
the cylinder. This level will be used for any programmed bath step
commanding
Level 2
.
The minimum valid value for this decision is equal to the value of
the
Level 1 Height
configured just before.
Use the same procedure to configure Levels 3 through 6 that you
used to configure Level 2. Keep in mind that each level must be
equal to or greater than the previous level. The maximum level
that can be configured is 15 inches (38 centimeters) for V_J mod-
els. The maximum setting for H_J models is 16 inches (40 centi-
meters). See
Table 9: Recommended Water Levels, page 43
recommended water levels.
Table 9.
Recommended Water Levels
Basket Dimension (from
model number)
Suggested Level 1 (Low Level) Suggested Level 6 (High Level)
Inches
Centimeters
Inches
Centimeters
30015
8
20
10
25
30022
8
20
10
25
36021
8
20
13
33
36026
8
20
13
33
42026
10
25
13
33
42032
10
25
13
33
Display or Action
Explanation
EXTRA WATER ?
0=NO, 1=YES
1
Select
1=Yes
only if this machine is equipped with an optional
third water valve. Configuring for extra water makes an addi-
tional programming decision available for bath steps, allowing
reuse of water drained from earlier baths, for example.
REUSE DRAIN ?
0=NO, 1=YES
1
Select
1=Yes
only if this machine is equipped with an optional
second drain valve. Configuring for reuse drain makes an