Pellerin Milnor Corporation
17
10. The
Manual button
(
) has no effect while a formula is running except when troubleshoot-
ing bath level errors. Pushing this button when the display says “Run Formula xx” initiates
manual mode, where the controls function as described in
2.1.2: Control Functions During
. For troubleshooting bath level problems, hold the
Signal Can-
cel
,
Manual
, and
Next buttons
simultaneously to display the raw pressure data and the actual
number of inches detected by the bath level pressure transducer.
11. The
Terminate button
(
) cancels all remaining steps in any running formula and initiates
the shutdown procedure for the machine. Formulas ended in this manner cannot be resumed.
12. The
Door Unlock button
(
) unlocks the door. For safety, you must also hold this button to
open or close the optional power-assisted door or to jog or tilt the machine.
2.1.2
Control Functions During Manual Operation
BNCJHP01.R02 0000189820 C.2 A.5 1/2/20 1:16 PM Released
Manual operation is used primarily for troubleshooting the machine by activating outputs and
viewing inputs.
1. The
Start button
(
), when pressed while the
Manual button
is held down, activates the
selected menu function. Depress the
Start
and
Manual buttons
simultaneously to view the
software date code. For other manual menus, release the
Start button
when the menu appears
on the display.
2. The
Run/Program keyswitch
has no effect on how the manual mode operates. However, the
status of the switch ( or –) is displayed in field F in the
Test Inputs
menu.
3. The
Run Indicator light
is not activated during manual operation.
4. At the manual menu, the
Scroll Down button
(
) displays the available menu items in re-
verse numeric order.
5. In the manual menu, the display presents user prompts and selected information. The software
date code and machine configuration are displayed; inputs and outputs and their respective
statuses are shown in those modes. Other menu selections display DIP switch settings, as well
as temperature and level testing information.
6. The
Scroll Up button
(
) displays the next higher numbered mode in the manual menu.
For example, pressing this button once will scroll from the
Software Date Code
mode to the
Test Inputs
mode.
7. The
Next button
(
) has no function in manual mode.
8. The
Signal Cancel button
(
) has no function in manual mode.
9. The
Operator Signal light
does not operate when the controller is in manual mode.
10. Use the
Manual button
(
) to enter manual mode when the machine is idle.
11. The
Terminate button
(
) cancels manual mode and returns the controller to the normal
operation or programming mode, depending on the setting of the
Run/Program
keyswitch.
Any outputs that were manually actuated while in manual mode are turned off.
Содержание E-P Plus