Pellerin Milnor Corporation
Figure 3.
Examples of Manifolds for Chemical Tubes. Your equipment can look different.
Close the line.
If the pump does not always close the line when it is off, use a shutoff valve to do this.
Do not let a vacuum occur.
Supply a vacuum breaker in the chemical line that is higher than the full level of the tank.
Flush the chemical tube with water.
If the liquid that stays in the tube between the pump and the machine can flow in the machine,
flush the tube with water after the pump stops.
Put the chemical tube fully below the inlet.
It is also necessary that there is no pressure in the chemical tube or tank when the system is off.
Figure 4.
A Configuration that Prevents Flow in the Machine When the Pump is Off (if the chemical
tube and tank have no pressure)
Schematic View
Legend
I.
Chemical inlet on the
machine
L.
Chemical tube
P.
Pump
T.
Chemical tank
Prevent Damage from Chemical Supplies and Chemical Systems