Chapter 2. Normal Machine Operation
PELLERIN MILNOR CORPORATION
Figure 10:
Select Local Formula
Screen
Display or Action
Explanation
0
7
Directly selects the formula you want to run (07, for example).
When you enter a two-digit number, the selected formula moves
to the top of the left column on this screen.
k
Toggles the column for formula selection if necessary. If the
desired formula is visible on the screen, but is in the opposite
column from the selection box, this keystroke moves the
selection box to the other column of formulas.
&
/
^
Move to the next or previous displayed formula in the current
column. If the desired formula is visible on the screen and in the
same column as the selection box, you can use these two keys to
move the selection box down or up to select the formula.
u
Confirm the selected formula. Place the selection box on the
formula you want to run, then press
u
to continue with the
normal operation procedures.
Supplement 1
About Load Weight and
Metered Water
Metered water
is available on Mark VI washer-extractors equipped with optional flow meters
on the incoming water lines. This feature allows the Mark VI controller to admit a quantity of
water proportional to the weight of goods you enter after selecting the formula. If you enter a
weight of 200 units when prompted, the machine will use twice as much water as if you entered
100 weight units. This option can save a significant amount of water if you enter accurate
weights for each load.