MSSM0712AE/2000266V
È
30022H7J AND 30022H8J PREVENTIVE MAINTENANCE
As required by the warranty, to ensure safe operation, and to achieve optimum performance and service life
from Milnor
®
washer-extractors, the schedules, instructions, and precautions herein must be strictly followed.
Ï
Preventive Maintenance Schedule
Component
Procedure
See FIGURE
Frequency
Door interlock
Test functioning for safe operation.
BMP990012
daily
Water seal grease point
Slowly grease at one location until
grease seeps from grease seal relief
FIGURES 1 and 3
monthly
Water inlet strainers
Clean as required
FIGURE 4
every four months
Foundation bolts
Check bolt tightness and wear.
Adjust or replace if necessary.
Dimensional
drawing
every four months
Drive train
Check belt tension and wear. Check
pulleys and other drive components
for wear. Replace if necessary.
FIGURE 5
every four months
Main bearing housing
Change lubricant.
FIGURES 2 and 3
every two years
Ê
Main Bearing Housing Preventive Maintenance
ELECTROCUTION HAZARD—High voltage is present inside electric boxes,
motors, and many other components. Power switches on machine disable only
control circuit power in certain boxes. You can be killed or seriously injured on
contact with high voltage.
☞
Lock OFF and tag out power at the wall disconnect before servicing.
ENTANGLE AND CRUSH HAZARD—Belts and pulleys can entangle and crush
body parts.
☞
Lock OFF and tag out power at the wall disconnect before servicing, except
where specifically instructed otherwise in this section.
☞
Permit only qualified maintenance personnel to perform these procedures.
MALFUNCTION HAZARD—Oil spilled on components may cause machine malfunction.
☞
Refill bearing housing carefully.
MACHINE DAMAGE HAZARD—Mixing incompatible lubricants will result in
severe machine damage.
☞
DO NOT mix different base lubricants.
☞
Before using a non-specified lubricant, consult the lubricant manufacturer
to determine compatibility.
Ï
Lubrication Specifications
Component
Lubricant/Type
Amount of Lubricant
Main bearing
housing
High quality SAE 50 (ISO 220)
heavy duty motor oil, non-detergent if available
22 fluid ounces (651 milliliters)
Water seal
grease
Shell Alvania EP LF (or equivalent)
Preventive Maintenance Schedule
Ê
Lubrication Procedures
See the appropriate main bearing drawing (if provided) during this procedure (see Table of Contents).
1. Remove the rear belt cover.
2. Remove the drain plug (FIGURE 3) on the bottom of the main bearing housing and allow the bearing housing
to drain completely. Inspect the leak-off, drained oil, and magnetic drain plug for water and/or metal parti-
cles. Water and/or metal particles can indicate worn or damaged seals and bearings. Install the drain plug.
3. Locate the oil fill plug (FIGURE 2) on the bearing housing. Clean the surrounding area and remove the
oil fill plug.
4. Refill the bearing housing. After refilling the bearing housing, reinstall the oil fill plug and clean any excess
lubricant from the machine.
Содержание 30022H7 Series
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 11: ...Section 1 Service and Maintenance ...
Страница 20: ... 3 4 3 3 4 4 0 0 12 0 2 ...
Страница 22: ... 00 3 4 8 4 8 3 9 0 01 0 12 0 2 ...
Страница 44: ......
Страница 45: ...Section 2 Drive Assemblies ...
Страница 53: ...Section 3 Shell Door and Assemblies ...
Страница 60: ......
Страница 61: ...Section 4 Water and Steam Piping and Assemblies ...
Страница 68: ......
Страница 69: ...Section 5 Chemical Supply Devices ...
Страница 75: ...Section 6 Control and Sensing Devices ...