OM-251387 Page 16
5-2. Selecting Input Voltage (230/460 Volt Models Only)
252018-C / 252019-A
!
Turn Off welding power
source, disconnect input
power, and check voltage
on input capacitors accord-
proceeding.
Check input voltage available at
site.
1
Voltage Selection View
Window
Check voltage selected in unit.
Changing selection is only neces-
sary if selected value does not
match available input voltage.
2
Relinking Board PC6
3
Mounting Screws
4
Receptacle RC8 (Connection
For 230 VAC Input Power)
5
Receptacle RC7 (Connection
For 460 VAC Input Power)
Move relinking board as needed
and connect plug PLG4 (in unit) to
RC8 or RC7 according to input
power voltage.
1
Tools Needed:
5/16 in.
2
5
3
4
3
.
Be sure to reinstall all four screws
securing relinking board in place.