OM-257 486 Page 8
SECTION 3 − SPECIFICATIONS
3-1.
Serial Number And Rating Label Location
The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.
3-2.
Unit Specifications
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 4-7 and 4-8 for information on con-
necting input power.
Input
Power
Rated
Output
Voltage
Range in
CV Mode
Amperage
Range in
CC Mode
Max.
Open-
Circuit
Voltage
RMS Amps Input at Rated Load Output, 60 Hz
3-Phase at NEMA Load Voltages and Class I
Rating
KVA
KW
230 V
380 V
400 V
460 V
3-Phase
350 A at 34
VDC, 60%
Duty Cycle
10−38 V
5−425 A
75 VDC
36.1
22.3
20.6
17.8
14.2
13.6
*See Section 3-5 for Duty Cycle Rating.
3-3.
Dimensions And Weight
Hole Layout Dimensions
(610 mm)
24 in.
(432 mm)
17 in.
(318 mm)
12-1/2 in.
804 801-A
A
D
C
B
E
G
F
A
(298 mm) 11-3/4 in.
B
(42 mm) 1-11/16 in.
C
(400 mm) 15-3/4 in.
D
(485 mm) 19-3/32 in.
E
(221 mm) 8-11/16 in.
F
(39 mm) 1-17/32 in.
G
1/4-20 UNC -2B thread
Weight
(36.3 kg) 80 lb
3-4.
Environmental Specifications
A. IP Rating
IP Rating
IP23
This equipment is designed for outdoor use. It may be stored, but is not intended to be used
for welding outside during precipitation unless sheltered.
IP23 2014−06
Содержание XMT 425 CC/CV
Страница 21: ...OM 257 486 Page 17 Notes...
Страница 29: ...OM 257 486 Page 25 Notes...
Страница 30: ...OM 257 486 Page 26 SECTION 7 ELECTRICAL DIAGRAM Figure 7 1 Circuit Diagram...
Страница 31: ...OM 257 486 Page 27 956142946 C...
Страница 36: ...Notes...
Страница 37: ......
Страница 38: ...Notes...