Complete Parts List available at www.MillerWelds.com
OM-258900 Page 28
5-9. Remote Receptacle Information
A
J
B
K
I
C L N
H
D M
G
E
F
*The remaining sockets are not used.
Socket*
Socket Information
24 VOLTS AC
A
24 volts ac. Protected by supplementary protector
CB4.
B
Contact closure to A completes 24 volt AC con-
tactor control circuit and keeps engine at Run
speed in all Wire modes.
REMOTE
OUTPUT
CONTROL
C
+10 volts dc output to remote control.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from
remote control.
F
Current feedback: 1 volt per 100 amperes.
H
Voltage feedback: 1 volt per 10 arc volts.
GND
G
Circuit common for 24 volts AC circuits.
K
Chassis common.
Notes
Содержание Trailblazer 325 Diesel
Страница 18: ...OM 258900 Page 14...
Страница 33: ...Complete Parts List available at www MillerWelds com OM 258900 Page 29 Notes...
Страница 47: ...Complete Parts List available at www MillerWelds com OM 258900 Page 43 259 872 258 899 C...
Страница 53: ...Complete Parts List available at www MillerWelds com OM 258900 Page 49 Notes...
Страница 54: ...OM 258900 Page 50 SECTION 10 ELECTRICAL DIAGRAMS Figure 10 1 Circuit Diagram For Welder Generator...
Страница 55: ...OM 258900 Page 51 258849 E...