3-8. Connecting Weld Cable
!
Turn Off wire feeder and
welding power source. Stop
engine on welding
generator.
1
User-Supplied Weld Cable
Follow wire manufacturer’s recom-
mendations for weld cable polarity.
2
User-Supplied Male
Connector
3
User-Supplied Female
Connector
Push female connector over male
connector, and turn 1/4 turn clock-
wise.
804 421-A
2
1
3
From Wire Feeder
Rear View
3-9. Weld Cable Sizes
NOTICE
−
The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is
100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine cable
size.
!
Turn off power before
connecting to weld out-
put terminals.
!
Do not use worn, dam-
aged, undersized, or
poorly spliced cables.
Weld Output
Terminals
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
100 ft (30 m) or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Welding
Amperes
10
−
60%
Duty
Cycle
AWG
(mm
2
)
60
−
100%
Duty
Cycle
AWG (mm
2
)
10
−
100% Duty Cycle
AWG (mm
2
)
100
4 (20)
4 (20)
4 (20)
3 (30)
2 (35)
1 (50)
1/0 (60)
1/0 (60)
150
3 (30)
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
3/0 (95)
200
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120) 4/0 (120)
250
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120) 2 ea. 2/0
(2x70)
2 ea. 2/0
(2x70)
300
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120) 2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 3/0
(2x95)
350
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120) 2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
400
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120) 2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
2 ea. 4/0
(2x120)
500
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
3 ea. 3/0
(3x95)
3 ea. 3/0
(3x95)
*
This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm
2
for metric use
***For distances longer than those shown in this guide, call a factory applications rep. at 920-735-4505 (Miller) or 1-800-332-3281 (Hobart)
Ref. S-0007-G 2009
−
08
Содержание SuitCase X-TREME 8VS CE
Страница 14: ...OM 226 288 Page 10 ...
Страница 25: ...OM 226 288 Page 21 4 3 Gun Consumables Information 235 264 A Notes ...
Страница 26: ...OM 226 288 Page 22 4 4 Wire Speed Control Settings Ref 222 307A Notes ...
Страница 30: ...OM 226 288 Page 26 SECTION 6 ELECTRICAL DIAGRAM 226 637 E Figure 6 1 Circuit Diagram For Wire Feeder ...