A complete Parts List is available at www.MillerWelds.com
OM-279299 Page 45
8-4. Aligning Drive Rolls and Wire Guide
!
Turn Off power.
View is from top of drive rolls
looking down with pressure
assembly open.
1
Drive Roll Securing Nut
2
Drive Roll
3
Wire Guide
4
Welding Wire
5
Drive Gear
Insert screwdriver, and turn screw
in or out until drive roll groove lines
up with wire guide.
Close pressure roll assembly.
Ref. 800 412-A
Correct
Incorrect
4
3
2
1
5
Tools Needed:
8-5. Error Messages
Message
Error
Remedy
Overtemp
Please wait while the welder cools
down
Inverter Module
Output Rectifier
Secondary Magnetics
Internal temperature of welder has exceeded the
maximum limit.
Wait for unit to cool down. If the fan is not run-
ning, contact authorized Miller service center.
Trigger Error
Release MIG gun trigger
MIG gun trigger is engaged on power up.
Release 4-pin trigger to clear error.
MIG gun is held during jog for more than 17 feet
of wire.
MIG gun trigger is engaged for more than 1 sec-
ond after the arc is broken.
After an overtemp error, the MIG gun trigger is
held after the welder has completed cooling.
MIG gun trigger is engaged while another
process is selected.
MIG gun trigger leads are shorted together.
Содержание Millermatic 255
Страница 54: ...OM 279299 Page 50 SECTION 10 ELECTRICAL DIAGRAM Figure 10 1 Circuit Diagram ...
Страница 55: ...OM 279299 Page 51 279043 C ...
Страница 64: ...Notes ...
Страница 65: ...Notes ...
Страница 66: ...Notes ...