OM-246 691 Page 19
input2 2012−05
!
Installation must meet all National and
Local Codes − have only qualified per-
sons make this installation.
!
Disconnect and lockout/tagout input
power before connecting input con-
ductors from unit. Follow established
procedures regarding the installation
and removal of lockout/tagout
devices.
!
Always connect green or green/yellow
conductor to supply grounding termi-
nal first, and never to a line terminal.
See rating label on unit and check input volt-
age available at site.
For Three-Phase Operation
1
Input Power Cord.
2
Disconnect Device (switch shown in the
OFF position)
3
Green Or Green/Yellow Grounding
Conductor
4
Disconnect Device Grounding Terminal
5
Input Conductors (L1, L2 And L3)
6
Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding ter-
minal first.
Connect input conductors L1, L2, and L3 to
disconnect device line terminals.
7
Over-Current Protection
Select type and size of over-current protec-
tion using Section 4-5 (fused disconnect
switch shown).
Close and secure door on disconnect device.
Follow established lockout/tagout procedures
to put unit in service.
B.
Connecting 3-Phase Input Power (Continued)
Notes
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.
Содержание MigMatic 220
Страница 19: ...OM 246 691 Page 15 Notes...
Страница 22: ...OM 246 691 Page 18 B 3 Phase input2 2012 05 Ref D5 GND PE Earth Ground L1 2 1 L2 L3 3 3 4 5 6 7 Tools Needed...
Страница 37: ...OM 246 691 Page 33 956142710 B Figure 7 2 Circuit Diagram for Migmatic 250 230 400 VAC...
Страница 38: ...OM 246 691 Page 34 956142711 F Figure 7 3 Circuit Diagram for Migmatic 220 DX 230 VAC...
Страница 39: ...OM 246 691 Page 35 956142712 E Figure 7 4 Circuit Diagram for Migmatic 250 DX 230 400 VAC...