OM-212296 Page 27
6-7.
Adjust Control
1
Adjust Control
The Adjust control is used to
change various sequence parame-
ters, and to select various se-
quences. Refer to the section for
the function in question for informa-
tion related to using the Adjust con-
trol.
1
6-8.
Sequence Push Button
1
Sequence Push Button
2
Sequence Push Button LED
3
Welding Sequence LED’s
3
2
1
.
For more information on Setting Se-
quence Parameters See Section 9-1.
•
The Sequence push button allows the
selection of welding sequences. Five weld-
ing sequences are available. The default
sequence is the Weld sequence. The Weld
sequence is active upon power up. Three
welding sequence LEDs are located above
the Sequence push button: Start, Crater,
and Preflow/Postflow. The applicable LED
illuminates to indicate the active welding se-
quence.
Welding sequences other than weld must
be set prior to initiating the arc. When the
unit enters a welding state, all sequence dis-
play modes are terminated and the weld dis-
play mode is activated.
If zero time is programmed for a timed se-
quence except for Weld, that sequence will
be skipped.
•
In the Weld sequence display mode, the Se-
quence push button LED is off. When the
Sequence push button is pressed, the Se-
quence push button flashes and the Start
LEDs flash. In this condition, the unit is in the
Start sequence display mode, and Start se-
quence parameters are shown in the dis-
plays.
•
When the Sequence push button pressed a
second time, the Crater sequence LED
flashes; the Sequence LED also remains
flashing. In this condition, the unit is in the
Crater sequence display mode, and the
Crater sequence parameters are shown in
the displays.
•
When the Sequence push button is pressed
a third time, the Preflow/Postflow sequence
LED flashes. The Sequence push button
LED remains flashing. In the Preflow dis-
play mode, the upper display shows the pre-
flow time, and PRE is shown in the lower
display. To change the preflow time, press
the upper display and turn the Adjust con-
trol.
To select between preflow (PRE) and post-
flow (POST), press the lower display button
and turn the Adjust control. When POST is
selected, the upper display is used to speci-
fy postflow time.
•
When the Sequence button is pressed a
fourth time, the unit returns to the Welding
sequence display mode.
6-9.
Flux Push Button
1
Flux Push Button
2
Flux Push Button LED
Pressing the Flux push button
toggles the flux valve control open
and closed. When the Flux push
button LED is lit, the flux valve con-
trol is open.
When the flux valve control is set to
“AUTO” (see Section 6-6), the flux
valve opens when the Start button
is pressed, and closes when the
last sequence is finished.
1
2