OM-239026 Page 22
7-4. Inspecting Filter And Spark Guard
245615
!
Turn off unit and disconnect
input power cord.
!
Do not operate unit without
filter or with dirty (plugged)
filter.
!
Clean or replace the filter
when dirty.
!
Allow cooling period before
inspecting or replacing filter,
or cleaning particle tray and
spark guard.
!
Do not breathe the particles
collected by the fume extrac-
tor. Wear approved safety
equipment (respirator,
gloves, long sleeve shirt)
when servicing filter and
spark guard. Dispose of
used element and collected
particles according to local,
state, and federal require-
ments.
!
Read and understand the
Material Safety Data Sheets
(MSDSs) and the manufac-
turer’s instructions for met-
als, consumables, coatings,
cleaners, and degreasers.
1
Latch
2
Hatch
3
Filter
4
Spark Guard
Release latches and open hatch.
Use filter handles to remove filter.
Clean or replace filter if dirty or
damaged.
Wipe off hatch. Remove particles
from inside of housing.
Remove spark guard (from behind
baffle).
Clean and inspect spark guard
screen. Replace spark guard if
screen wires are broken or missing.
Install spark guard.
Install filter.
Close hatch and secure with
latches.
Tools Needed:
2
3
1
4
Содержание FILTAIR MWX-S
Страница 4: ......