OM−265 411 Page 2

1-3.

Remote 14 Receptacle Information

805 497-A

A

J

B

K

I

C

L

N

H

D

M

G

E

F

Socket

Socket Information

15 VOLTS DC

OUTPUT
CONTACTOR

A

Contactor c15 volts DC, referenced to G.

B

Contact closure to A completes 15 volts DC
contactor control circuit and enables output.

REMOTE

OUTPUT

CONTROL

C

Output to remote control; +10 volts DC output to
remote control.

D

Remote control circuit common.

E

0 to +10 volts DC input command signal from
remote control.
*Reconfigurable as input for Output Enable (Weld
Stop) − used to remotely stop the weld outside the
normal welding cycle. Connection to the D socket
must be maintained at all times. If the connection
is broken, output stops, and Auto Stop is dis-
played.

Output

Signals

F

Current feedback; +1 volt DC per 100 amperes.

H

Voltage feedback; +1 volt DC per 10 volts output.

I*

Valid arc indication closed to socket G with valid
arc. Electrical specifications: open collector tran-
sistor (see Section 1-4 for connection example).

J*

Arc length control lockout closed to socket G dur-
ing Initial and Final Amperage and Slope, and dur-
ing the background time of a <=10 Hz pulse wave-
form. Electrical specifications: open collector tran-
sistor (see Section 1-4 for connection example).

COMMON

G

Return for all output signals: F, H, I, J and A.

CHASSIS

K

Chassis

Serial
Communication
Bus

L**

Modbus Common (RS485 Common)

M**

Modbus D1 (RS485 B+)

N**

Modbus D0 (RS485 A-)

.

If a remote hand control, like the RHC-14, is connected to the Remote 14 receptacle, some current value above min. must be set on the remote
control before the Panel or Remote contactor is turned on. Failure to do so will cause current to be controlled by the panel control, and the remote
hand control will not function.
*Available with optional Automation Expansion memory card.
**Available with optional Modbus Expansion memory card. Modbus serial communication provides access to all front panel parameters and
machine functionality. See Owner’s Manual 265415 for a list of Modbus registers. Modbus expansion also includes functionality of Automation
and AC Independent Amplitude (Dynasty only) Expansions.

Sockets G and K

 

are electrically isloated from each other.

1-4.

Simple Automation Application

R

CR1

+

CR1

To User Equipment

Coil resistance plus R
should be chosen to
limit current to 75 mA

User supplied power
up to 27 volts DC
peak

Pin I, J: Collector

Pin G: Emitter