OM-254063 Page 21
SECTION 6 − MAINTENANCE & TROUBLESHOOTING
6-1.
Routine Maintenance
!
Disconnect power
before maintaining.
.
Maintain more often
during severe conditions.
3 Months
Replace
unreadable
labels.
Clean and
tighten
weld
terminals.
Repair or
replace
cracked
weld
cable.
Check
14-pin cord.
Check gas
hose and
fittings.
Check gun
cable.
Replace
cracked
parts.
6 Months
Blow out or vacuum
inside. During heavy
service, clean
monthly.
Or
Clean
drive rolls.
6-2.
Brush Inspection And Replacement
Ref. 137 390-C / S-0816
1
Motor
2
Brush Cap
Remove brush cap.
3
Brush
Replace brush if it becomes
chipped or broken, or if less than
1/4 in. (6.4 mm) of brush material is
left. Do not include spring boss as
part of the 1/4 in. measurement.
Install brush so that curved surface
on end of brush matches curve of
motor, and secure with cap.
Repeat procedure for other brush.
Tools Needed:
1
2
3
1/4 in. (6 mm)
Minimum Length
5/8 in. (16 mm)
New Length
Replace
Damaged
Brushes
Содержание D-74 MPa Plus