OM-236 949 Page 22
5-6. Activating The Dry Charge Battery (If Applicable)
!
Always wear a face shield,
rubber gloves and protective
clothing when working on a
battery.
Remove battery from unit.
1
Vent Caps
2
Sulfuric Acid Electrolyte
(1.265 Specific Gravity)
3
Well
Fill each cell with electrolyte to
bottom
of well (maximum).
!
Do not overfill battery cells.
Wait ten minutes and check electro-
lyte level. If necessary, add electro-
lyte to raise to proper level. Reins-
tall vent caps.
4
Battery Charger
!
Read and follow all instruc-
tions supplied with battery
charger.
5
5 Amperes For 30 Minutes
Charge Time
6
30 Amperes For 12 Minutes
Charge Time
Charge battery. Disconnect charg-
ing cables and install battery.
When electrolyte is low, add
only distilled water to cells to
maintain proper level.
1
Tools Needed:
2
4
+
−
3
drybatt 12008
−
01
−
S-0886
5
6
30 A
5 A
5-7. Connecting The Battery
1/2 in
−
+
Tools Needed:
805 177-A / Ref. 217 357-D / S-0756-C
!
Connect negative (
−
) battery
cable last.
Close door after connecting
battery.
Содержание Big Blue 300 D
Страница 31: ...OM 236 949 Page 27 Notes Welding Symbols Ref AWS ANSI A2 4 ...
Страница 37: ...OM 236 949 Page 33 6 6 Fuel Hour Gauge Descriptions ...
Страница 40: ...OM 236 949 Page 36 8 2 Maintenance Label ...
Страница 50: ...OM 236 949 Page 46 SECTION 9 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For Welding Generator ...
Страница 51: ...OM 236 949 Page 47 236 892 A ...