OM-223 Page 18
SECTION 3
−
OPERATION
3-1. Controls
Ref. ST-162 502-B
5
6
1
2
3
4
1
Voltage Adjustment Control
Turn control clockwise to increase voltage.
2
Digital Meters
3
Power Switch With Indicator Light
4
High Temperature Shutdown Light
5
Remote Voltage Control Switch
For front panel control, place switch in Panel
position. For remote control, place switch in
Remote position, and connect remote de-
vice (see Section 2-8).
6
Output Switch
For front panel control of output, place switch
in Panel position. For remote control of out-
put, place switch in Remote position, and
connect remote device (see Section 2-8).
Y
Turn Off power before connecting re-
mote device.