Operating Instructions

4. Pan / Tilt Drag Control.

The  Arrow  25  Fluid  Head  offers  5  selectable  positions  of 
fluid drag + zero setting in the Pan and Tilt. The settings are 
equally stepped from light drag in position 1 up to heavy drag 
in  position  5,  the  drag  plates  are  completely  disengaged  in 
position zero.

  Do not Pan or Tilt the Fluid Head whilst adjusting PAN or TILT 

DRAG CONTROL or whilst the PAN & TIL DRAG CONTROL 
is between settings.

  The drag setting can be changed at any tilt or pan angle.

5. Pan/Tilt Lock Control.

The  Arrow  25  Fluid  Head  offers  high  capacity  calliper  disc 
brake system to hold the Fluid Head in a fixed pan and/or tilt 
position. Camera position will not change when applying or 
releasing the Pan/Tilt locks.

  Do not pan or tilt the Fluid Head whilst the PAN or the TILT 

LOCK is partially applied.

6. Illumination.

The  Arrow  25  Fluid  Head  offers  illumination  of  the  PAN  & 
TILT  DRAG  CONTROL  settings,  BUBBLE  LEVEL  and  PAN  & 
TILT INDICATOR when the low ambient light conditions exist. 
Illumination can be achieved by pressing the ILLUMINATION 
BUTTON once. The light will switch off after 10 seconds.

 Illumination Button

Counter Balance Selector

Tilt Drag Setting   

Pan Drag Setting

Tilt Indicator

Bubble Level

Tilt Drag Knob   

Pan Drag Knob

Pan Indicator

Fig. 7

8

Содержание arrow 25

Страница 1: ...arrow 25 arrow 25 Fluid Head OPERATOR S MANUAL 1022 Arrow 25 Fluid Head ...

Страница 2: ...Features and Controls Fig 1 Sliding Platform Camera Screws Tilt Lock Tilt Drag Control Bubble Level 1 4 and Pin Adaptor Camera Plate Quick Release Knob Safety Tab Counterbalance Selector Pan Drag Control ...

Страница 3: ...2 Pan Handle Pan Handle Clamp Sliding Platform Lock Clamp Nut Tilt Lock Pan Lock Threaded Stud Fig 2 Features and Controls ...

Страница 4: ...andard 100 mm tripods as well please refer to manufactures manual for mounting details Attaching removing the camera Please use this manual to familiarise yourself with the operation of the Arrow 25 Fluid Head and observe these instructions to prevent any damage to your equipment Ensure that all equipment is operating correctly and free from defects and damage also please ensure that the tripod is...

Страница 5: ... see Fig 6 Camera Platform Type Quick release sliding platform with 70 mm travel Camera Plate 1 4 3 8 and 1 4 Locating Pin Carriage Mini DV mount Mounting Base Ø100 mm Ball Levelling Ball Level Range 15o Handle Standard black anodised pan handle with adjustable angle Temperature range o C o F 40o to 65o 40o to 149o Construction Lightweight diecast Aluminium alloy moulded reinforced plastics Sealin...

Страница 6: ...ead and the PAN HANDLE CLAMP if this occurs then unwind the PAN HANDLE CLAMP further 1 2 Ensure that the TRIPOD BOWL is approximately horizontal Place the Fluid Head into the TRIPOD BOWL adjust the BUBBLE LEVEL fig 4 such that the bubble is inside the black circle and tighten the CLAMP NUT 1 3 Set the initial control settings as follows see Figure 1 2 Select Counterbalance to position 4 top setting...

Страница 7: ...ards or forwards until a balance point C of G is achieved It is recommended to identify this point on the camera as it will be useful in step 2 5 2 4 Attach the CAMERA PLATE to the camera or the QUICK RELEASE TRIPOD ADAPTOR such that the C of G mark on the camera is approximately 10 20 mm behind the front edge of the CAMERA PLATE then securely tighten the screws 2 5 Align the CAMERA PLATE with the...

Страница 8: ...ing 3 1 For safety ensure that Counterbalance position 4 is selected 3 2 Hold the camera and release the TILT LOCK then gently tilt the camera from a horizontal position forward then backward and observe its response If the Camera Springs Back to the horizontal position then a lower Counterbalancesettingisrequired selectCounterbalance position 3 and recheck select lower setting again if necessary ...

Страница 9: ...uid Head offers high capacity calliper disc brake system to hold the Fluid Head in a fixed pan and or tilt position Camera position will not change when applying or releasing the Pan Tilt locks Do not pan or tilt the Fluid Head whilst the PAN or the TILT LOCK is partially applied 6 Illumination The Arrow 25 Fluid Head offers illumination of the PAN TILT DRAG CONTROL settings BUBBLE LEVEL and PAN TI...

Страница 10: ...brasives harsh detergents and solvents Battery Replacement The Arrow 25 Fluid Head uses a single GP23A type 12 Volt battery for Illumination Miller recommends the following batteries to provide long life performance Duracell MN21 23 Eveready A23 or Vinnic L1028 Using a Phillips Head 1 screw driver remove the two RETAINING SCREWs BATTERY DOOR and the old battery Insert the new battery as shown in fi...

Страница 11: ...equirement may void warranty It is advisable to notify Miller or a Miller Authorised Service Agent if a change of performance is observed as a result of dropping or rough usage For information regarding sales and service of Miller products or for your nearest Miller representative please contact us via our website or at the following MILLER CAMERA SUPPORT EQUIPMENT 30 Hotham Parade Artarmon Sydney...