![Miller 907684001 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/miller/907684001/907684001_owners-manual_1796041054.webp)
.
A complete Parts List is available at www.MillerWelds.com
OM-270536 Page 46
8-3. Accessing Control Panel Menu: DC Stick
1
Menu Button
Press Menu button to cycle through
parameters that can be set.
2
Parameter Display
3
Setting Display
4
Amperage Adjustment Control
Rotate amperage adjustment control
to adjust parameter setting.
.
Parameter automatically returns
to amperage setting 15 seconds
after amperage adjustment con-
trol is inactive.
1
30%
DIG
110A
2
3
4
110A
Or
247218-C
[DIG]* Arc Force Control:
Controls the amount of additional amperage at low
voltage (short arc length) conditions. Adjust the
force of the arc for different joint configurations and
electrodes. Range is OFF
−
100%. Features
PRO-Set values for both 6010 and 7018 electrodes
Amperage Control:
Controls the welding amperage output. Limits the
maximum output of a remote amperage device.
*PRO
−
SET
provides PROfessionally developed
SETtings for the weld process. To use PRO
−
SET,
press the menu button to display the parameter and
adjust the amperage adjustment control until PRO
−
SET flashes on the display. PRO
−
SET flashes one
time and reveals the professional setting for the para-
meter.
*CARB-ARC
at one step above DIG’s 100% CARBon
ARC Gouging can be selected.
HF START
Schedule 1
Schedule 2
LIFT ARC
Содержание 907684001
Страница 6: ......
Страница 46: ...A complete Parts List is available at www MillerWelds com OM 270536 Page 38 Notes...
Страница 78: ...OM 270536 Page 70 SECTION 14 ELECTRICAL DIAGRAMS Figure 14 1 Circuit Diagram For Dynasty 210 255980 G...
Страница 79: ...OM 270536 Page 71 Figure 14 2 Circuit Diagram For Maxstar 210 255981 H...
Страница 88: ...Notes...
Страница 89: ...Notes...
Страница 90: ...Notes...