TM-353 Page 10
Syncrowave 250
3-8.
Remote 14 Receptacle
Socket*
Socket Information
A
24 volts ac.
B
Contact closure to A completes 24 volts ac contactor control
circuit.
C
Command reference; 0 to +10 volts dc output to remote control.
A
J
B
K
I
D
Remote control circuit common.
C
L
N
H
D
M
G
F
A
E
0 to +10 volts dc input command signal from remote control.
E
F
ST-154 795-C
K
Chassis common.
*The remaining sockets are not used.
3-9.
115 Volts AC Duplex Receptacle And Shielding Gas Connections
Ref. ST-154 795-C / Ref. ST-157 858
Y
Turn Off power before
connecting to receptacle.
1
115 V AC Receptacle
Receptacle is protected from over-
load by circuit breaker CB1 (see
Section 7-2).
2
Gas Valve In Fitting
3
Gas Valve Out Fitting
Fittings have 5/8-18 right-hand
threads
4
Cylinder Valve
Open valve slightly so gas flow
blows dirt from valve. Close valve.
5
Regulator/Flow Gauge
6
Flow Adjust
Typical flow rate is 20 cfh (cubic feet
per hour) (9.4 L/min)
7
High Frequency Control (see
Section 4-1)
4
5
6
1
7
3
2
Содержание SYNCROWAVE 250