OM-236 684 Page 20
4-11. Basic Sub Arc (SAW) Welding
.
Customer must supply the following: power source, power source control cable, wire drive assembly, wire drive assembly cable, drive rolls, gun,
welding wire, weld cables, remote voltage sense leads, and flux system for the desired application.
A. Basic Sub Arc (SAW) Equipment Connections
804 724-A
!
Turn off welding power
source and weld control, and
disconnect input power be-
fore making connections.
.
Use remote voltage sense
leads in all applications.
.
Suggested size for remote volt-
age sense wire is 12 gauge or
larger.
.
For better performance for
most Sub Arc (SAW) applica-
tions, make connections to the
high inductance weld output
terminal.
.
Polarity: For DCEP (Reverse
Polarity), connect weld cables
and voltage sense leads as
shown. For DCEN (Straight
Polarity), reverse weld cables
and voltage sense leads.
Wire Drive
Assembly
Workpiece
Flux
System
Flux
Valve
+
+
−
Strip 1T Terminal P
1T Terminal N
From Terminal
From Terminal Strip
10-Pin Motor
Control Cord
Weld Cables
HDC Controller
14-Pin Welding
Control Cord
Power Source
Submerged
Arc
193 587-A
77
76
75
32
–
2
4
31
C
E
REMOTE
115 VAC
24 VAC
REMOTE
GND
REMOTE
OUTPUT
REMOTE
REMOTE
VOLTAGE
POWER
CONTROL
CONTACTOR
CONTACTOR
SENSE
D
I
J
A
B
N
P
K M
L
–
–
–
–
ON/OFF
Содержание Subarc DC 650
Страница 14: ...OM 236 684 Page 10...
Страница 36: ...OM 236 684 Page 32 SECTION 7 ELECTRICAL DIAGRAM Figure 7 1 Circuit Diagram...
Страница 37: ...OM 236 684 Page 33 228 467 B...
Страница 44: ...Notes...
Страница 45: ...Notes...
Страница 46: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...