OM-235 825 Page 24
SECTION 6
−
MAINTENANCE &TROUBLESHOOTING
6-1. Routine Maintenance
!
Disconnect power
before maintaining.
.
Maintain more often
during severe conditions.
n
= Check
Z
= Change
~
= Clean
l
= Replace
* To be done by Factory Authorized Service Agent
Reference
Every
3
Months
l
Damaged Or Unreadable
Labels
l
Repair Or Replace
Cracked Weld Cable
~
Clean And Tighten Weld
Terminals
Every
6
Months
OR
~
Inside Unit
~
Clean Drive Rolls
6-2. Overload Protection
Ref. 803 809-D
1
Supplementary Protector CB1
CB1 protects unit from overload. If
CB1 opens, unit shuts down.
Reset supplementary protector.
1