background image

OM-530 Page 38

Description

Quantity

Part

No.

Dia.

Mkgs.

Model

Basic

W/Pulser

W/Electro

slope

W/Pulser

Electroslope

Item

No.

Figure 9-4. Panel, Front w/Components

(Fig 9-1 Item 16) (Continued)

13

C19

028 294

CAPACITOR, polye met film 1uf 250VDC

1

1

1

1

. . 

. . . 

. . . 

. . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

14

S3

011 974

SWITCH, polarity (300 & 400A models) (Fig 9-5)

1

1

1

1

. . . 

. . . . 

. . . 

. . . . 

. . . 

. . . . 

. . . . . 

14

S3

048 153

SWITCH, polarity (500 & 600A models) (Fig 9-8)

1

1

1

1

. . . 

. . . 

. . . 

. . . . 

. . . 

. . . . 

. . . . . 

129 755

RECEPTACLE, w/leads (consisting of)

1

1

1

1

. . . . . . . . . . . . . . 

. . . 

. . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

15

C11

144 906

LEAD ASSEMBLY, elect

1

1

1

1

. . 

. . . 

. . . . 

. . . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

15

C12

144 907

LEAD ASSEMBLY, elect

1

1

1

1

. . 

. . . 

. . . . 

. . . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

15

C13

144 908

LEAD ASSEMBLY, elect

1

1

1

1

. . 

. . . 

. . . . 

. . . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

15

C14

144 909

LEAD ASSEMBLY, elect

1

1

1

1

. . 

. . . 

. . . . 

. . . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

16

RC2

143 976

CONNECTOR w/SOCKETS, (consisting of)

1

1

1

1

. . 

. . 

. . . . 

. . . . . . . 

. . . 

. . . . 

. . . . . 

079 534

CONNECTOR, circ skt push-in 14-18ga

. . . . . . . . . . . . . . 

. . . . . . 

Amp 66358-6

14

14

14

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . 

. . . 

134 734

CONNECTOR, circ 14 pin plug Amp 213571-2

. . . . . . . . . . . . . . 

. . . 

134 731

CONNECTOR, circ pin push-in 14-18ga Amp 213603-1

. . . . . . . . . . . . . . 

. . . 

079 739

CONNECTOR, circ clamp str rlf sz 17-20

. . . . . . . . . . . . . . 

. . . 

Amp 206322-2 (or)

143 922

CONNECTOR, circ clamp str rlf sz 17-20 

. . . . . . . . . . . . . . 

. . . 

Amp 206070-3

17

R5

030 738

POTENTIOMETER, C std slt 1/T 2W 500K ohm

1

1

1

1

. . . 

. . . 

. . . 

. . . . . 

. . . 

. . . . 

. . . . . 

18

R3

605 828

RHEOSTAT, WW 50W 1.5 ohm

1

1

1

1

. . . 

. . . 

. . . 

. . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

19

S1,2

011 609

SWITCH, tgl SPDT 10A 125V

2

2

2

2

. . 

. . . 

. . . 

. . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

20

CB1

020 278

CIRCUIT BREAKER, man reset 1P 15A 240VAC

1

1

1

1

. . 

. . 

. . . 

. . . . 

. . . 

. . . . 

. . . . . 

21

C1

113 501

CAPACITOR

1

1

1

1

. . . 

. . . . 

. . . 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

22

RC1

604 176

RECEPTACLE, str dx grd 2P3W 15A 125V

1

1

1

1

. . 

. . 

. . . 

. . . . . . . . . 

. . . 

. . . . 

. . . . . 

073 690

PLUG, str grd armd 2P3W 15A 125V P & S 5266DF

. . . . . . . . . . . . . . 

. . . 

23

039 047

TERMINAL, pwr output red (consisting of)

2

2

2

2

. . . . . . . . . . 

. . . 

. . . . . . . . . . 

. . . 

. . . . 

. . . . . 

24

601 976

SCREW, .500-13 x 1.50 hexhd pln stl

1

1

1

1

. . . . . . . . . . 

. . . . 

. . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

25

039 045

TERMINAL BOARD, black

1

1

1

1

. . . . . . . . . . 

. . . . 

. . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

25

039 049

TERMINAL BOARD, red

1

1

1

1

. . . . . . . . . . 

. . . . 

. . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

26

601 880

NUT, stl hex jam .500-13

1

1

1

1

. . . . . . . . . . 

. . . . 

. . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

27

039 044

BUS BAR, term bd

1

1

1

1

. . . . . . . . . . 

. . . . 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

28

601 879

NUT, stl hex full .500-13

1

1

1

1

. . . . . . . . . . 

. . . . 

. . . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

29

***

Part of Spot Timer Circuit Card (TD3)

. . . . . . . . . . . . . . . 

. . . 

30

S201

***011 609

SWITCH, tgl SPDT 15A 125VAC

1

1

1

1

. . 

. . . 

. . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

31

****

Part of Preflow Timer Circuit Card (TD2)

. . . . . . . . . . . . . . . 

. . . 

32

S200 ****011 609

SWITCH, tgl SPDT 125VAC

1

1

1

1

. . 

. . . 

. . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

33

C9

136 736

CAPACITOR

1

1

1

1

. . . 

. . . 

. . . 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

34

010 476

BUSHING, strain relief .625 ID x .570mtg hole

1

1

1

1

. . . . . . . . . . 

. . . 

. . . . . . 

. . . 

. . . . 

. . . . . 

35

+008 259

DOOR, access front

1

1

1

1

. . . . . . . . . 

. . . 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

36

605 583

CATCH, spr loaded door

2

2

2

2

. . . . . . . . . . 

. . . 

. . . . . . . . . . . . . . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

37

134 327

LABEL, warning general precautionary

1

1

1

1

. . . . . . . . . . 

. . . 

. . . . . . . . . . . . . 

. . . 

. . . . 

. . . . . 

38

**041 213

PULSER, (Fig 9-6)

1

1

. . . . . . . . . 

. . . 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

. . . . . . . . . . . . 

39

**041 212

ELECTROSLOPE 9, (Fig 9-7)

1

1

. . . . . . . . . 

. . . 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

. . . . . 

052 997

COVER, opening module electroslope

1

1

. . . . . . . . . . . . . . 

. . . 

. . . . . . . . . . . . . 

. . . 

052 998

COVER, opening module pulser

1

1

. . . . . . . . . . . . . . 

. . . 

. . . . . . . . . . . . . . . . . . . 

. . . . . . . . . . 

*Part of Optional Meter Kit (see Optional Equipment for kit numbers).
**Optional
***Part of 041 407 Optional Spot Weld Timer.
****Part of 041 404 Optional Preflow Timer
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
BE SURE TO PROVIDE MODEL AND SERIAL NUMBER WHEN ORDERING REPLACEMENT PARTS.

Содержание KC237900

Страница 1: ...lser And Electroslope Processes Description TIG GTAW Welding Enables Welding Power Source to provide TIG as well as Stick capability OM 530J May 1993 Eff w Serial Number KC237900 Stick SMAW Welding Sh...

Страница 2: ...alue established in 1929 This Owner s Manual is designed to help you get the most out of your Miller products Please take time to read the Safety precautions They will help you protect yourself agains...

Страница 3: ...Gas Coolant Postflow Control 12 4 5 Remote Hand Controls 13 4 6 High Frequency Switch 13 4 7 High Frequency Control 14 4 8 Meters Optional 14 4 9 Pulser Switch Pulser Models Only 14 4 10 On Time Contr...

Страница 4: ...8 5 General Installation Procedures 29 8 6 Guidelines For Installation Of High Frequency Assisted Arc Welding Power Sources 31 8 7 Installation Guidelines Checklist 31 SECTION 9 PARTS LIST Figure 9 1...

Страница 5: ...power source Owner s Manual 1 2 SAFETY ALERT SYMBOL AND SIGNAL WORDS The following safety alert symbol and signal words are used throughout this manual to call attention to and identify different lev...

Страница 6: ...ges 3 2 TRANSPORTING METHODS This unit is equipped with a lifting eye for moving during installation Weight capacity of the lifting eye only allows for supporting the unit and welding power source WAR...

Страница 7: ...n a proper manner The valves are labeled ensure that connections are cor rect see Figure 4 1 and Sections 3 11 and 3 12 7 Install proper welding cables see welding power source s Owner s Manual for co...

Страница 8: ...allation is com plete and the TIG Unit is ready to be put in oper ation 9 Open access door on lower front of TIG Unit re move component bag and route short intercon necting cord approximately 4 ft or...

Страница 9: ...in a proper manner 10 Maintain a proper lead dress around fan and wind tunnel and route leads through access hole in cover into TIG Unit 11 Connect the two leads to the terminal labeled 230V on rear...

Страница 10: ...n of lead harnesses etc 4 Carefully slide Electroslope unit into opening on front panel of TIG Unit Secure Electroslope with the four screws removed from blank panel in Step 2 5 Route leads from Elect...

Страница 11: ...t be employed 3 Route cord through supplied connector on rear of TIG Unit and attach it to terminals labeled 115V on terminal strip TE1 located on center mounting panel toward back of TIG Unit see Fig...

Страница 12: ...ng operation 2 Mount Preflow ON OFF switch S200 in the 1 2 in 12 7 mm diameter hole using supplied hardware 3 Mount Preflow Time control with attached printed circuit card assembly TD2 in the 3 8 in 9...

Страница 13: ...a proper lead dress inside the unit l Replace left side panel and top cover 9 For Models Prior to Serial No HK261770 a Locate lead 32 between transformer T1 and in tegrated rectifier SR2 Splice lead 3...

Страница 14: ...controls 5 Attach supplied knob to Spot Time control shaft B Electrical Installation Figure 3 2 IMPORTANT Before preceeding with this installation familiarize yourself with the circuit diagram provid...

Страница 15: ...and recirculating coolant system make connections from the coolant system directly to the torch hoses Do not use water connections on the TIG Unit The COOLANT IN and COOLANT OUT fittings have 5 8 18...

Страница 16: ...DJUSTMENT control on the TIG Unit al ways functions as a fine amperage adjustment cali brated in percent of the AMPERAGE ADJUSTMENT control on the welding power source If a remote control is used and...

Страница 17: ...r is deenergized the postflow timer begins to time out the selected period of postflow time Once the timer has timed out the gas and coolant valves close and thereby cut off shielding gas and cool ant...

Страница 18: ...g as the momentary contact switch is held closed Provided that an arc has been established releasing the momen tary contact switch will deenergize the high frequency If an arc is not established the h...

Страница 19: ...is operational only when the PULSES switch is in the ON position Rotating the PULSES SECOND control in a clockwise direction increases the pulse frequency The scale surrounding the PULSES SECOND contr...

Страница 20: ...OM 530 Page 16 ST 009 477 D ST 007 648 G...

Страница 21: ...nit is in the PANEL position whenever the Electroslope is to be utilized The AMPERAGE ADJUSTMENT control on the TIG Unit has complete control of the amperage at this point 4 15 PERCENTAGE INITIAL AMPE...

Страница 22: ...ding the PREFLOW TIME control is calibrated in seconds to aid in the selec tion of a preflow time period suited to the individual weld ing operation As soon as the remote contactor control switch has...

Страница 23: ...safety information 5 1 GAS TUNGSTEN ARC WELDING WARNING Read and follow safety informa tion at beginning of entire Section 5 before proceeding 1 Make all necessary connections as instructed in Section...

Страница 24: ...Select and obtain proper electrode and insert into electrode holder 7 Depress the POWER switch on the welding power source to the ON position 8 Connect the 115 volts ac plug from the TIG Unit to its p...

Страница 25: ...used for ac or dc electrode positive welding before beginning the welding operation Weld amperage causes the tungsten elec trode to form the balled end The diameter of the end should not exceed the d...

Страница 26: ...RECOMMENDED The figures listed are intended as a guide and are a composite of recommendations from American Welding Society AWS and electrode manufacturers S 0009 8 88 Green Band Red Band Brown Band 6...

Страница 27: ...ncy out put A Fuse F1 Fuse F1 is a 3 ampere glass fuse located on the center mounting panel below terminal strip 1T If this fuse should open there would be no remote control of the contactor B Fuse F2...

Страница 28: ...to welding power source output terminals Check connections Be sure that they are correct and secure see Sections 3 3 and 3 4 No output from welding power source See welding power source Owner s Manual...

Страница 29: ...OM 530 Page 25 SECTION 7 ELECTRICAL DIAGRAMS Circuit Diagram No SC 121 852 A Diagram 7 1 Circuit Diagram For TIG Unit With Options...

Страница 30: ...OM 530 Page 26 Circuit Diagram No SA 045 288 C Diagram 7 2 Circuit Diagram For Postflow Timer Circuit Diagram No SB 088 800 A Diagram 7 3 Circuit Diagram For Pulser Optional...

Страница 31: ...OM 530 Page 27 Circuit Diagram No SC 080 063 E Diagram 7 4 Circuit Diagram For Electroslope Optional...

Страница 32: ...OM 530 Page 28 Circuit Diagram No SA 096 935 A Diagram 7 5 Circuit Diagram For Preflow Timer Optional Circuit Diagram No SA 049 109 A Diagram 7 6 Circuit Diagram For Spot Timer Optional...

Страница 33: ...GTAW process In these cases it will take several thousand volts to cause an electrical spark to jump this gap between the electrode and the work creating an in itial path of ionization that the arc c...

Страница 34: ...ungrounded metal objects or unshielded wiring in the immediate vicinity conducted some distance and reradiated This can be a troublesome source of inter ference 8 4 LOCATION Locate the high frequency...

Страница 35: ...ogether as by welding each piece of metal to all other adjacent pieces For metal buildings adjacent metal panels should be bolted or welded together at fre quent intervals All windows and doorways sho...

Страница 36: ...p setting to the minimum setting given in this manual 8 Secure all service and access doors before operat ing 9 Visualize the welding zone as a sphere with a 50 ft 15 m radius centered on a point betw...

Страница 37: ...ower source 1 1 1 1 2 006 017 COVER box used when unit is mounted on power source 1 1 1 1 3 026 627 GASKET lifting eye cover 1 1 1 1 4 008 267 LIFT EYE 1 1 1 1 5 Fig 9 2 PANEL control rear w component...

Страница 38: ...tg hole Field installed units only 3 3 3 3 057 359 BLANK snap in nyl 375mtg hole 2 2 2 2 110 089 CABLE interconnecting consisting of 1 1 1 1 141 162 CONNECTOR PINS consisting of 1 1 1 1 134 731 CONNEC...

Страница 39: ...r 115 250V 1 1 1 1 6 Shunt 030 081 SHUNT meter 50MV 500A 300A 1 1 1 1 6 Shunt 030 084 SHUNT meter 50MV 600A 400A 1 1 1 1 6 Shunt 079 388 SHUNT meter 50MV 800A 500 600A 1 1 1 1 7 012 571 HOLDER fuse mi...

Страница 40: ...ilm 10uf 250VAC 2 8 C3 17 096 761 CAPACITOR mica 002uf 10000VDC 2 9 010 885 STRIP conductor 4 602 042 SCREW 10 32 x 1 00 rndhd slt brs 1 10 111 181 LINK connecting 1 11 020 623 SPARK GAP ASSEMBLY cons...

Страница 41: ...3 3 5 019 603 KNOB ball 1 1 1 1 6 129 060 PANEL front 1 1 1 1 7 P1 025 701 FILTER HF dc volts amp meter 2 2 2 2 8 S4 011 611 SWITCH tgl DPDT 15A 125V 1 1 1 1 9 R1 072 462 POTENTIOMETER w shaft lock co...

Страница 42: ...1 1 1 21 C1 113 501 CAPACITOR 1 1 1 1 22 RC1 604 176 RECEPTACLE str dx grd 2P3W 15A 125V 1 1 1 1 073 690 PLUG str grd armd 2P3W 15A 125V P S 5266DF 23 039 047 TERMINAL pwr output red consisting of 2 2...

Страница 43: ...isting of 1 5 011 645 CONTACT ASSEMBLY movable switch consisting of 2 6 011 075 SPRING pressure contact switch 1 7 011 953 CONTACT switch 2 8 011 074 SPRING pressure contact switch 1 9 010 805 HANDLE...

Страница 44: ...NNECTOR rect skt 24 18ga Amp 350980 1 12 5 073 756 STAND OFF 6 32 x 625 lg 5 6 010 116 GROMMET rbr 375 ID x 500mtg hole 1 7 072 307 CIRCUIT CARD filter 1 8 027 144 TUBING nylon 150 ID x 250 OD x 250 2...

Страница 45: ...NECTOR SOCKETS consisting of 1 079 747 CONNECTOR rect skt 24 18ga Amp 350980 1 12 079 748 CONNECTOR rect 18skt plug Amp 1 640250 8 1 079 747 CONNECTOR rect skt 24 18ga Amp 350980 1 18 5 073 756 STAND...

Страница 46: ...itch plrt 1 8 601 836 NUT brs hex 250 20 jam hvy 4 9 052 413 STUD brs 250 20 x 875 2 10 103 633 BUS BAR shorting switch plrt 4 11 103 634 MOUNTING BOARD cmpnt plrt switch 1 12 024 694 BEARING plrt swi...

Страница 47: ...A 1 1 4 SR2 005 882 RECTIFIER integ 6A 600V 1 1 5 052 194 TIMER delay on make 0 60 sec consisting of 1 1 6 039 449 BRACKET mtg circuit card 1 1 7 TD1 045 874 CIRCUIT CARD timer 1 1 8 CR1 070 744 RELAY...

Страница 48: ...ect skt 24 18ga Amp 350980 1 7 097 922 KNOB pointer illustrated on Fig 9 4 1 006 301 BRACKET mtg component 1 106 625 SPACER nyl 250 OD x 140 ID x 1 000mtg hole 4 See Fig 9 4 for additional parts 041 4...

Страница 49: ...Notes...

Страница 50: ...mperage and weld with 1 8 in 3 2 mm Stick electrode without returning to the power source AMPSET can be considered when cable connected box type remote hand controls are impractical when operating a l...

Страница 51: ...ting Torches Remote Controls Accessory Kits Replacement Parts No labor Spoolmate 185 Spoolmate 250 Canvas Covers Miller s True Blue Limited Warranty shall not apply to 1 Consumable components such as...

Страница 52: ...complete and retain with your personal records Always provide Model Name and Serial Style Number Call 1 800 4 A Miller or see our website at www MillerWelds com to locate a DISTRIBUTOR or SERVICE AGEN...

Отзывы: