2
Control Panel
Input
Power
Three-
Phase
Single-
Phase
Three-
Phase
Single-
Phase
Rated
Output
250 A at 30 V,
100% Duty Cycle
300 A at 32 V,
60% Duty Cycle
180 A at 27.2 V,
100% Duty Cycle
225 A at 29 V,
60% Duty Cycle
500 A at 40 V,
100% Duty Cycle
600 A at 44 V,
60% Duty Cycle
360 A at 34 V,
100% Duty Cycle
450 A at 38 V,
60% Duty Cycle
Welding
Amperage
Range
5 – 350 A
5 – 350 A
5 – 700 A
5 – 700 A
Model
Dynasty
350
Dynasty
700
Max.
Open-Circuit
Voltage
75 VDC
10 –15 VDC*
75 VDC
10 –15 VDC*
75 VDC
10 –15 VDC*
75 VDC
10 –15 VDC*
Net
Weight
135.5 lb
(61 kg)
with
TIGRunner
®
308 lb
(140 kg)
198 lb
(90 kg)
with
TIGRunner
®
370 lb
(168 kg)
Specifications
(Subject to change without notice.)
Amps Input at Rated Load Output, 50/60 Hz
208 V 230 V 400 V 460 V 575V
KVA
KW
29
26
15
13
10
10.3
9.9
35
32
18
16
13
12.7
12.1
35
32
—
15
12
7.4
6.8
47
43
—
21
17
9.8
9.1
75
68
39
34
27
27
26
97
88
51
44
35
35
34
82
74
—
37
30
17
16
115
104
—
52
42
24
22
Dimensions
H: 24-3/4 in (629 mm)
W: 13-3/4 in (349 mm)
D: 22 in (559 mm)
with TIGRunner
®
H: 45-1/8 in (1146 mm)
W: 23-1/8 in (587 mm)
D: 43-3/4 in (1111 mm)
H: 34-5/8 in (879 mm)
W: 13-3/4 in (349 mm)
D: 22 in (559 mm)
with TIGRunner
®
H: 55-1/8 in (1400 mm)
W: 23-1/8 in (587 mm)
D: 43-3/4 in (1111 mm)
Conforms to European standards.
Certified to both the Canadian and U.S. Standards for welding equipment.
*Indicates sense-voltage for Lift-Arc TIG and Low OCV Stick.
1. Memory
36 Combinations
(9 AC TIG)
(9 AC Stick)
(9 DC TIG)
(9 DC Stick)
2. Polarity
AC/DC
3. Process/
TIG: HF Impulse, Lift Arc
Arc Starting
STICK: Adaptive Hot Start
4. Output Control
Standard Remote,
2T Trigger Hold,
Output ON
5
.
Pulser Control
Pulses per Second DC : 0.1– 5000 PPS
AC : 0.1 – 500 PPS
Peak Time
5 – 95%
Background Amps 5 – 95%
6. Sequencer Control
Initial Amps
Dynasty 350: 5 –350 A
Dynasty 700: 5– 700 A
Initial Slope
0.0 – 50.0 Seconds
Final Slope
0.0 – 50.0 Seconds
Final Amps
Dynasty 350: 5 –350 A
Dynasty 700: 5– 700 A
7. Gas/DIG Preflow
0.0 – 25.0 Seconds
Postflow
Auto Postflow,
Adjust 0.0 – 50 Seconds
DIG
0 – 100%
8. AC Waveshape
EN Amperage
5 – 350 A /5 – 700 A
EP Amperage
5 – 350 A/5 – 700 A
Balance
30 – 99%
AC Frequency
20– 400 Hz
9. Amperage Control
10. Encoder Control
11. Ammeter Display
12. Voltmeter Display
Additional Setup Parameter Values
Programmable Starts
Amperage
5 – 200 A
Time
1– 200 Milliseconds
Polarity EP,
EN
Additional Triggers
3T, 4T, Mini Logic,
4T Momentary
Waveshapes
Advance Squarewave,
Soft Squarewave, Sine
Wave, Triangular wave
Amplitude Lock
EN EP Same,
EN EP Independent
Spot/Weld Timer
0.0 – 999 Seconds
OCV
Low OCV, Normal OCV
Lockouts
Four levels
Arc Timer
0.0 – 9999 Hours
and 0 – 59 Min
Cycle Counter
0 – 999,999 Cycles
Meter Calibration
±0 – 20.0 A mps
±0 – 20.0 Volts
f
13
10
9
11
12
1
2
3
6
4
5
7
8
Control Panel Parameter Values