OM-2252 Page 19
4-10. Remote 14 Receptacle Information
Socket*
Socket Information
24 VOLTS AC
A
24 volts ac. Protected by circuit breaker CB2.
B
Contact closure to A completes 24 volts ac contactor control circuit.
115 VOLTS AC
I
115 volts ac. Protected by circuit breaker CB1.
J
Contact closure to I completes 115 volts ac contactor control circuit.
C
Output to remote control; +10 volts dc in MIG mode.
REMOTE
OUTPUT
D
Remote control circuit common.
OUTPUT
CONTROL
E
0 to +10 volts dc input command signal from remote control.
M
Remote mode select.
A/V
AMPERAGE
F
Current feedback; +1 volt dc per 100 amperes.
AMPERAGE
VOLTAGE
H
Voltage feedback; +1 volt dc per 10 arc volts.
GND
G
Circuit common for 24 and 115 volts ac circuits.
GND
K
Chassis common.
*The remaining sockets are not used.
4-11. Connecting Remote Control
Ref. 800 166-D / Ref. S-0004-A / S-0750
!
Turn off power before con-
necting to Remote 14 recep-
tacle.
1
Remote 14 Receptacle RC14
Connect remote control to RC14.
A
J
B
K
I
C L N
H
D M
G
E
F
1
OR
OR