OM-628 Page 6
8.
Routine Maintenance
Y
Disconnect power
before maintaining.
3 Months
Blow Out Heat
Exchanger Fins
Y
Clean coolant strainer. Severe conditions
may require more frequent cleaning (continu-
ous use, high/low temperatures, dirty envi-
ronment, etc.). Failure to properly clean
coolant strainer voids pump warranty.
6 Months
Replace
Cracked
Hoses
Replace
Unreadable
Labels
Change
Coolant (If
Using Water)
12 Months
Oil Motor
Change
Coolant (If
Using 043 809
or 043 810
Coolant)
3/8 in
Tools Needed:
9.
Coolant Maintenance And Oiling Motor
ST-801 195-B / Ref. ST-801 194
1
Coolant Filter
Unscrew housing to clean filter.
Changing coolant: Drain coolant by
tipping unit forward. Fill with clean
water and run for 10 minutes. Drain
and refill.
2
Motor
Remove plugs and put about 15
drops of SAE 20 motor oil into each
oil port. Replace plugs.
.
If replacing hoses, use hoses
compatible with ethylene gly-
col, such as Buna-n, Neo-
prene, or Hypalon. NOTE:
Oxy-acetylene hoses are not
compatible with any product
containing ethylene glycol.
1
2
Содержание COOLMATE 3