OM-210 540 Page 29
Sample Auto-Calibration Routine For Fanuc Robot
1:
Call Safehome
2:
J P[1] 40% Fine
Arcstart [10.0Volts, 100.0IPM]
3:
L P[2] 10.0 sec Fine
Arc End [0.0Volts, 0.0IPM, 0.0Sec]
4:
Wait 1.00 (Sec)
5:
J P[3] 40% Fine
Arcstart [44.0Volts, 1000.0IPM]
6:
L P[4] 10.0 sec Fine
Arc End [0.0Volts, 0.0IPM, 0.0Sec]
7:
Call Safehome
Sample Auto-Calibration Routine For ABB Robot
Move J home, v500, z50, tweldgun;
Arcl \ on, *, v500, sm1, wd1, wv0, z50, tweldgun;
Arcl \ off, *, v500, sm1, wd1, wv0, z50, tweldgun;
WaitTime 5;
Arcl \ on, *, v500, sm1, wd2, wv0, z50, tweldgun;
Arcl \ off, *, v500, sm1, wd2, wv0, z50, tweldgun;
Move J home, v500, z50, tweldgun;
*Seam Data values must all be set at zero.
Weld Data 1:
Weld Data 2:
weld_sched:=0
weld_sched:=0
weld_speed:=5
weld_speed:=5
weld_voltage:=10
weld_voltage:=44
weld_wfs:=100
weld_wfs:=1000
org_weldspeed:=0
org_weldspeed:=0
org_weldvoltage:=0
org_weldvoltage:=0
org_weldwfeed:=0
org_weldwfeed:=0
Содержание Auto-Axcess 450
Страница 14: ...OM 210 540 Page 10...
Страница 51: ...OM 210 540 Page 47 Notes...
Страница 53: ...OM 210 540 Page 49 207 903 G Part 1 Of 2...
Страница 54: ...OM 210 540 Page 50 Figure 8 2 Circuit Diagram For Welding Power Source Part 2 Of 2...
Страница 55: ...OM 210 540 Page 51 207 903 G Part 2 Of 2...
Страница 56: ...OM 210 540 Page 52 Figure 8 3 Circuit Diagram For 72 Pin Robot Interface...
Страница 57: ...OM 210 540 Page 53 219 266 C...
Страница 58: ...OM 210 540 Page 54 Figure 8 4 Circuit Diagram For Peripheral Motor Interface...
Страница 59: ...OM 210 540 Page 55 219 267 B...