Miller Edge MEL-K20 Скачать руководство пользователя страница 2

P.O. Box 159 • West Grove, PA 19390 • 800-220-3343 • 610-869-4422 • Fax: 610-869-4423 • www.milleredge.com

6809 South Harl Ave., Suite A • Tempe, AZ 85283 • 800-887-3343 • 480-755-3565 • Fax: 480-755-3558

2-9.    Momentarily press the TEST button. The Green Tx Data LED should flash. 

(

The Red Low Battery LED will only light when the batteries fall below 2.4v.

)

2-10.  Mount the Transmitter to the door or gate using #6 - 20 x 3/4” self-drilling screws.The mounting holes are 

located under the Top Lid Screws. Mount the transmitter with the wire strain relief facing down or to the side.

2-11.  Replace the cover on the Transmitter and tighten the screws taking care to align the lid.

*

Note the alignment pin located in the upper left corner.

3-

Install Receiver and Test

 3-1.  Remove lid of the Receiver Unit.

3-2.  Set the Group (red) and Address (blue) switches to 

match the transmitter settings.

3-3.  Mount the receiver close to the operator and in-the-line-of-sight

of the transmitter using the mounting holes, as shown.

3-4. *Connect the receiver’s PE (Photo-Eye) output to the operator’s 

PE input terminals using Green and White wires. 

(Operator terminal label naming may differ. Contact factory for 

support). 

3-5.  Connect the Black and Red wires to a 12 or 24V ac/dc source. 

3-6.  Attach the antenna to the receiver RF board.

3-7.  

Preliminary Test :

Confirm that the Transmitter and Receiver are powered ON.

Activate the Safety Edge (or monitored device). 

The Address Valid Yellow LED on the Receiver should

flash momentarily.

If the Address Valid LED does not flash, check that the

Group and Address switches match the transmitter 

settings. Confirm that the Photo-Eye and Safety Edge 

LEDs are lit while the safety edge is held active. 

Note that the Photo-Eye and Safety Edge LEDs

go OFF when the Edge is released.

3-8. Replace the Receiver Lid taking care to slip

the Antenna through the lids’ grommet.

*Certain installations may require an alternative wiring

scheme. Please consult factory for assistance. 

4-

Safety Test

4-1.  While moving the door in the downward direction

or the gate in the desired direction, momentarily 

activate the Safety Edge and confirm that the 

door or gate stops and reverses direction.            

(4) CORNER 

MOUNTING HOLES

LID

ANTENNA

MOUNTING
TABS (2)

RECEIVER
ENCLOSURE

FIGURE (3-4)

MEL-K20_Inst_20140708

MEL-K20_Inst_20140708_WPE Instuctions  7/16/14  12:01 PM  Page 2

Содержание MEL-K20

Страница 1: ...oup switch is set to 1 the Address switch may be set to any position between 0 and B The remaining positions C D E and F are reserved for factory test P O Box 159 West Grove PA 19390 800 220 3343 610 869 4422 Fax 610 869 4423 www milleredge com 6809 South Harl Ave Suite A Tempe AZ 85283 800 887 3343 480 755 3565 Fax 480 755 3558 MEL K20_Inst_20140708 Model MEL K20 INSTALLATION INSTRUCTIONS IMPORTA...

Страница 2: ... the operator s PE input terminals using Green and White wires Operator terminal label naming may differ Contact factory for support 3 5 Connect the Black and Red wires to a 12 or 24V ac dc source 3 6 Attach the antenna to the receiver RF board 3 7 Preliminary Test Confirm that the Transmitter and Receiver are powered ON Activate the Safety Edge or monitored device The Address Valid Yellow LED on ...

Страница 3: ...ble Entrance Grommet for 15 2 diameter cables Cable Connections Screw clamp type terminal blocks for 18 26 awg wire Addressing Group Switch 2 position slide switch selectable as 0 or 1 Address Switch Selectable from 0 9 and A F See Address setting in the Tx setup section Dimensions 4 00 w x 4 74 h x 1 00 d Indicator Lights Rx Address Valid Yellow LED Indicates reception of message with our selecte...

Страница 4: ...cause harmful interference to radio or television reception which may be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Re orient or relocate the receiver antenna 2 Increase the separation between the equipment and the receiver 3 Connect the equipment into an outlet on a circuit different from that...