Technical Specifications
Power Requirements: 12/24V (10VDC minimum), 100mA max
Pulse Output: 325Hz, 15%, nominal
Range: 33 feet max., 6 feet min
Detector Wavelength: 880nm (Infrared)
Indicator Lights: Green LED for Power, Red LED for Fault
Dimensions: 1.0” x 1.1”, 38” or 74” tall
P.O. Box 159 • West Grove, PA 19390 • 800-220-3343 • 610-869-4422 • Fax: 610-869-4423 • www.milleredge.com
6809 South Harl Ave., Suite A • Tempe, AZ 85283 • 800-887-3343 • 480-755-3565 • Fax: 480-755-3558
LC-K36/K72_Inst_20150521
4-
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which may be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
1- Re-orient or relocate the receiver antenna
2- Increase the separation between the equipment and the receiver
3- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
4- Consult the dealer or an experienced radio/TV technician for help.
Changes or Modifications Not Expressly Approved By The Party Responsible For Compliance Could Void The
User’s Authority To Operate The Equipment.
Installation Cont’d - Electrical Connections
Emitter
Receiver
Light Curtain
Operator
Red
Black
Green
White
Red
Black
MIRCU-02
Controller
Common
Safety Input
12/24 VAC/DC
12/24 VAC/DC
Figure 1
Figure 2
Note: The red & black wires on each
light curtain stick also need to be
connected to 12/24 VAC/DC power.
MIRCU-02 Controller
Connect to
24V Power
Connect to
Operator
Safety Input
Connect the green
& white wires from
the MLC Receiver