2-1. Unpack the tube and identify which stick is the Emitter (2 wires) and
which is the Receiver (4 wires). The Receiver typically mounts on
the same side as the operator.
2-2. Identify the preferred location, usually close to the door tracks on
the inside of the door opening.
2-3. Attach the brackets to any available mounting points, using the screws
provided or other appropriate hardware. One bracket should go
approximately 6” below the top and another 6” above the bottoms of the
sticks. For the 6-foot sticks, an additional bracket should be added in
the middle.
2-4. Make sure the brackets are all in-line. The functional operating
distance between Emitter and Receiver is between 6 feet and 33 feet.
2-5. Press the sticks into the brackets. The flat surface should
be facing across the door opening so that the sticks are
pointing at each other and the bottoms are resting on the floor.
2-6. Wiring consists of connecting 12/24 VAC/DC power to the emitter,
receiver and the MIRCU-02 controller terminals marked “AC” on
TB2. Also, the green and white wire from the receiver connects to
the MIRCU-02 at TB1. Lastly the “RLY” terminals on the MIRCU-02
connect to your operator’s safety inputs. See Figures 1 & 2 on back.
2-7. Confirm that the Green LED is ON at the bottom of both sticks.
2-8. The Red LED on the receiver indicates either an obstruction or a
mis-alignment. The light curtains have a wide acceptance angle and
should align easily. Test proper operation of the sticks by standing in
the opening and observing the Red LED turning ON.
2-9. Test for proper operation with the operator and door.
P.O. Box 159 • West Grove, PA 19390 • 800-220-3343 • 610-869-4422 • Fax: 610-869-4423 • www.milleredge.com
6809 South Harl Ave., Suite A • Tempe, AZ 85283 • 800-887-3343 • 480-755-3565 • Fax: 480-755-3558
LC-K36/K72_Inst_20150521
Model # LC-K36/K72
INSTALLATION INSTRUCTIONS
IMPORTANT:
READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.
Parts List
Kit Contents:
1. Light Curtain Emitter: 36” or 72”
2. Light Curtain Receiver: 36” or 72”
3. Four or Six Mounting Brackets
4. Hardware Bag
5. Installation Instructions
6. MIRCU-02 Controller
1-
PART NUMBER
2-
Installation
The LC-K36/K72 Light Curtain is a failsafe light curtain that can be used in place of a single beam photo-eye. It provides
additional protection for the area above the floor, protecting people and vehicles more effectively than a single-beam eye.
Light Curtain
Receiver (left) Emitter (right)
Mounting Brackets
MIRCU-02 Controller
LC-K36_K72_Inst_20150521.qxp_WPE Instuctions 5/21/15 9:00 AM Page 1
For more information, please visit www.devancocanada.com or call toll free at 855-931-3334