background image

2-1.  Unpack the tube and identify which stick is the Emitter (2 wires) and 

which is the Receiver (4 wires). The Receiver typically mounts on   

the same side as the operator.

2-2.   Identify the preferred location, usually close to the door tracks on 

the inside of the door opening.

2-3.   Attach the brackets to any available mounting points, using the screws

provided or other appropriate hardware. One bracket should go  

approximately 6” below the top and another 6” above the bottoms of the

sticks. For the 6-foot sticks, an additional bracket should be added in 

the middle.

2-4.   Make sure the brackets are all in-line. The functional operating

distance between Emitter and Receiver is between 6 feet and 33 feet. 

2-5.   Press the sticks into the brackets. The flat surface should 

be facing across the door opening so that the sticks are 

pointing at each other and the bottoms are resting on the floor.

2-6.   Wiring consists of connecting 12/24 VAC/DC power to the emitter,         

receiver and the MIRCU-02 controller terminals marked “AC” on 

TB2. Also, the green and white wire from the receiver connects to 

the MIRCU-02 at TB1. Lastly the “RLY” terminals on the MIRCU-02 

connect to your operator’s safety inputs. See Figures 1 & 2 on back.

2-7.   Confirm that the Green LED is ON at the bottom of both sticks.

2-8.   The Red LED on the receiver indicates either an obstruction or a

mis-alignment. The light curtains have a wide acceptance angle and 

should align easily. Test proper operation of the sticks by standing in 

the opening and observing the Red LED turning ON.

2-9.   Test for proper operation with the operator and door.

P.O. Box 159 • West Grove, PA 19390 • 800-220-3343 • 610-869-4422 • Fax: 610-869-4423 • www.milleredge.com

6809 South Harl Ave., Suite A • Tempe, AZ 85283 • 800-887-3343 • 480-755-3565 • Fax: 480-755-3558

LC-K36/K72_Inst_20150521

Model # LC-K36/K72

INSTALLATION  INSTRUCTIONS

IMPORTANT: 

READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

Parts List

Kit Contents:

1.    Light Curtain Emitter: 36” or 72”

2.    Light Curtain Receiver: 36” or 72”

3.    Four or Six Mounting Brackets

4.    Hardware Bag 

5.    Installation Instructions

6.    MIRCU-02 Controller

1-

PART NUMBER

2-

Installation

The LC-K36/K72 Light Curtain is a failsafe light curtain that can be used in place of a single beam photo-eye. It provides

additional protection for the area above the floor, protecting people and vehicles more effectively than a single-beam eye. 

Light Curtain

Receiver (left) Emitter (right)

Mounting Brackets

MIRCU-02 Controller

LC-K36_K72_Inst_20150521.qxp_WPE Instuctions  5/21/15  9:00 AM  Page 1

For more information, please visit www.devancocanada.com or call toll free at 855-931-3334