background image

3-

 

INSTALL RECEIVER 

-Open box, remove lid from the MRF-01 

receiver. 

-Position receiver on operator, so that 

its wiring will reach the operator 

terminal strip. Keep in mind that the 

Green antenna wire must be exposed to  

the AW12-RF Transmitter/Air Wave™ 

Switch. It cannot be behind any type of 

metal. 

-Connect the Red (+) & Black (-) to your 

24VAC/DC source. The White wire 

connects to a low voltage COMMON 

terminal. The Yellow wire connects to 

your EDGE/SAFETY terminal. 

 

4-

 

PROGRAMMING 

-Apply power to the receiver. 

-Green Power LED stays on; Channel 1 

Red LED will be blinking.  

-To enter “Learn” mode simply press 

your fingertip onto CH1 (in the LEARN 

BUTTON section of the PCB). The Red 

LED remains on and the Amber Learn 

LED will begin to blink. 

-Activate the edge & note the Red & 

Amber LED’s will blink alternately 

rapidly. Then the Red LED will go out & 

the Amber LED remains on. 

-Channel 1 is now programmed. 

-To start-over/erase programming, 

press and hold CH1 again for 3 seconds, 

LED’s will blink for 5 seconds & then go 

into fault mode. 

 

5-

 

TEST SAFETY EDGE 

-Ensure that your door stops/reverses 

when safety edge is activated during 

close cycle. 

 

 

 

 

 