Page 5 of 17                                                  rev 103020                                           Millennia Media HV-316 

 

 

 

 
Front Panel Functions 

 

The 3/8” thick hand

-machined aluminum front panel 

consists of 48 LED status indicators and a two-digit 

numerical display.  

 

Ælogic software is required to operate the HV-316.  

The most current version can be downloaded at 

Ælogic Weblink

. Scroll down to the Downloads 

section. It requires a computer running MS Windows 
10 or higher.

 

 

1.

 

Unit ID Display

 

 Indicates unit number assigned 

to preamp

.

 

2.

 

Power Indicator

 

 Decimal point indicates unit 

has power. It takes about 20 seconds after 

power up before the Unit ID Display comes on.

 

 

3.

 

Input Level & Phantom Power Indicator

 

 

Green indicates levels -46 dBFS and higher.  Red 

indicates 0 dBFS. Amber indicates phantom 

power is on. 

 

4.

 

Auxiliary Power

 

 Indicates 12V auxiliary 

(redundant) power source is powering unit. 

 

5.

 

Power Switch

 

 Turns the unit on and off. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear Panel Functions 

 

1.

 

AC Power 

 

IEC power inlet, 80-264 VAC 47-63 Hz 

 

2.

 

MIDI Connection 

 

Allows remote control of the 

HV-316 using MIDI protocol. Use with Yamaha 

break-out cable ZP893500  
 

3.

 

Ethernet 

 

Dante audio networking and Ælogic 

control. Ælogic is only available on the Network 

Primary connector 

 

4.

 

Network Reset

 

 Restore to factory default 

settings. Static IP address 192.168.1.221, Netmask 

255.255.255.0 

 

HV316 must be powered off.  

 
Insert a small non-metallic object into the reset 

opening on the read of the unit. You should feel a 

slight click when the reset button is depressed. 

 

Turn on the unit while continuing to hold the reset 

button. 

 

When the unit processor has reset it will display “00” 

in the Unit ID display on the front of the unit. 

 

Release the reset switch on the rear. The unit will 

continue to boot.  

 

When the ID Display switches to the selected Unit 

ID, the device is ready to use. It will have the factory 

profile and will be set to Static IP address 

192.168.1.221, Netmask 255.255.255.0. 

 

5.

 

12 Volt Redundant (Auxiliary) Power 

 

Connect only Millennia approved optional backup 

power supply here. 

 

6.

 

Unit ID Selector 

 

Address Select

 

Rotary 

Switch sets Unit ID. The front panel numeric 

display changes to reflect the value selected 

here.  If connected to a network, the power 

needs to be cycled for the change to take effect 

in Ælogic. 

 

7.

 

Mic Inputs 

 

Eight channels of 

microphone-level input wired in the AES59/ 

Tascam format

.  

 

8.

 

Analog Output Option 

 

DB25s wired in the 

AES59/Tascam format for analog outputs. This 

option must be added at the factory. 

 

9.

 

Reserved DB25

 

 for future options. 

 

 

Address 

Unit ID 

Address 

Unit ID 

10 

11 

12 

13 

14 

15 

16 

2  3 

4  6 

Содержание HV-316

Страница 1: ...HV 316 Remote Control Microphone Preamplifier Owner s Manual...

Страница 2: ...Green Icon 9 Purple Icon 9 Blue Icon 9 Gray Icon 9 Unit ID Conflict 9 Unit Status Dialog 9 Overview 10 Control Section 10 Control Layout 10 Unit Naming and Unit Name Dialog Box 11 POLarity Flip 11 PAD...

Страница 3: ...ge Do not attempt to use the HV 316 in near or around water or in unusually moist environments such as near a sink or swimming pool Prevent liquids or any other materials or objects from spilling or f...

Страница 4: ...s shipments be honored more than 10 days after ship date Read this manual carefully and completely before attempting to use the HV 316 Improper operation could result in damage to product It is the us...

Страница 5: ...ngs Static IP address 192 168 1 221 Netmask 255 255 255 0 HV316 must be powered off Insert a small non metallic object into the reset opening on the read of the unit You should feel a slight click whe...

Страница 6: ...n the protection software on when finished You need to allow logic all permissions to access your network Failing to do so will prevent the software from seeing the Millennia Preamps connected If you...

Страница 7: ...68 1 2nn HV 316 ID nn Be sure the computer s wired Ethernet connection is set to IP address 192 168 1 200 There are many ways to do this and Microsoft occasionally changes the setup menus As of this w...

Страница 8: ...o access the network that you have chosen to use your HV 316s Dynamic Host Configuration Protocol DHCP is also an option for IP Address but we don t recommend using it unless you are familiar with net...

Страница 9: ...n HV 3R only Functioning Normally Local Mode Remote unit is functioning normally but is in the local mode HV 3R only if the unit is in Local mode when logic is started it won t appear Be sure to chang...

Страница 10: ...e the scroll bar at the bottom of the screen It allows the user to quickly scroll to any unit in the network You can also move the Control Section by using the Left and Right arrow keys on the keyboar...

Страница 11: ...3 of that channel s mic input Button illuminates yellow You must disable RBN before 48V can be enabled Caution do not insert or extract a mic with the phantom power on It can damage the microphone an...

Страница 12: ...d the channel reverts to linked mode Linked Mute Linked Mute parameters will turn on and off together unless Mute linked channels is unchecked in the Preferences dialog box Setup Preferences Mute link...

Страница 13: ...ile Save ctrl S will save any updates or changes to the project unless a new name is desired use File Save As shift ctrl S Scene Window Underneath the Scene Window there are four buttons Recall New De...

Страница 14: ...onal Appending and Saving Scenes Whenever a change is made to any parameter or function an asterisk will appear next to the active scene in the Scene Window with the exception of the Blank Scene The a...

Страница 15: ...Z Undo 10 levels Double Click Group Title in Link Matrix Lists channels that are members of the group Double Click on unit icon in Unit Status box Gives voltage temperature and network data of unit Do...

Страница 16: ...og output option 22 dBu analog option Phantom Input Impedance 1 kHz 6 750 ohms Output Impedance 24 3 Ohms analog option Phantom Powering 48 V dc 2 V dc 15 ma per channel Power Consumption 100 watts ma...

Страница 17: ...ll be accompanied by Windows based control software called Logic offering visual access to hardware control functionality and scene management The device shall be the Millennia HV 316 Warranty US and...

Отзывы: