The following Table 3. lists the ports operating modes based on the DIP switch
position.
PORT 1
PORT 2
PORT3
PORT4
SW
1
2
3
4
ON
Half-Duplex
Half-Duplex
Half-Duplex
Half-Duplex
OFF
Full-Duplex
Full-Duplex
Full-Duplex
Full-Duplex
Table 3.
Four ports 100Base-FX Fiber Module DIP switch functions
3-3. LED Descriptions
There are two LED indicators for each of the Fiber connection ports. If there is no
connection to a port, the corresponding LED indicators are not lit.
•
Link/Activity
. This LED indicator is green when there is a connection secured
to a device (a link) to the corresponding port. The LED indicator blinks when
there is a transmission of data (activity) taking place at the corresponding port.
•
Duplex Mode/Collision
. This LED indicator is orange when the
corresponding port is operating in Full Duplex mode. When the corresponding
port is operating in Half Duplex, the LED indicator is not lit. When collisions
are occurring at the corresponding port, the LED indicator blinks.
4. 1000Base-SX/LX Fiber Module
LK ACT
MIL-S6603LX
FD COL
Figure 7.
1000Base-SX/LX Front View
When installed into a Switch hub, the 1000Base-SX/LX Module provides 1 Gigabit
Ethernet ports which can connect the Switch to a Gigabit Backbone Switch or
Server with Gigabit NIC.
1000BASE-SX
"
In Multimode, the fiber optic segment cannot exceed 220m(62.5/125
µ
m) or
500m(50/125
µ
m) in length.
1000BASE-LX
"
In Multimode, the fiber optic segment cannot exceed 550m(62.5/125
µ
m) or
550m(50/125
µ
m) in length. In single mode the fiber optic segment cannot
exceed 10km(9/125
µ
m).
4-1. 1000Base-SX/LX Fiber Module Features
!
Conforms to IEEE 802.3z draft 4.2 and 802.3x standard
!
1x1000Base-SX/LX Ethernet Port