Instructions for the installer
13
AT
BE
CH
DE
DK
ES
FI
FR
GB
IE
IT
LU
NL
NO
PT
SE
It is possible to connect the gas in the following ways:
•
using iron or copper
rigid pipe
;
•
using uninterrupted
stainless steel
flexible pipe
with a mechanical fitting conforming to
standards regulations in force (maximum length of extended pipe
2000 mm
). The pipe should
be connected straight to the elbow of the ramp;
•
by inserting a
flexible rubber pipe
conforming to standards regulations in force. This pipe
should be coupled straight to the rubber-holder
P
corresponding to the gas used, and locked
with a clamp
F
conforming to standards regulations in force. In the latter case, check the expiry
date printed on the pipe and replace it before that date.
LPG
NATURAL GAS