Acquisition Control
MIKROTRON GmbH
5
‐
2
Acquistion Control
Tip:
Settings can only be
changed if image acquisi
‐
tion is stopped.
The following commands allow to make settings required for image
acquisition and to control an external trigger.
The following commands are availabel:
AcquisitionMode
This feature is used to set the device into a certain acquisition mode.
Up to now, only the mode continuous is available.
Name
Access
Length [Bytes]
Register Interface
Page
AcquisitionMode
R/W
4
Enumeration
AcquisitionStart
W
4
Command
AcquisitionStop
W
4
Command
TriggerSelector
R/W
4
Enumeration
TriggerMode
R/W
4
Enumeration
TriggerSource
R/W
4
Enumeration
TriggerActivation
R/W
4
Enumeration
TriggerCount
R/W
4
Integer
TriggerDebouncer
R/W
4
Integer
AcquisitionBurstFrameCount
R/W
4
Integer
TriggerSoftware
WO
4
Integer
ExposureMode
R/W
4
Enumeration
ExposureTime
R/W
4
Integer
ExposureTimeMax
R
4
Integer
AcquisitionFrameRate
R/W
4
Integer
AcquisitionFrameRateMax
R
4
Integer
Access
read / write
Type
enumeration
In
continuous
the camera records continuously a sequence of
frames until it is stopped by the command
AcquisitionStop
Out
the selected mode
Remark
frame acquisition can be stopped with the feature
AcquisitionStop
Содержание EoSens CAMMC1186
Страница 1: ...EoSens 1 1CXP Camera Reference Guide V1 2...
Страница 74: ...CHAPTER 11 Custom Features The chapter informs about the connected device on page 11 3...
Страница 87: ...APPENDIX A Technical Data...
Страница 89: ...APPENDIX B Spectral Response...
Страница 91: ...APPENDIX C Bayer Pattern...
Страница 94: ...APPENDIX D Camera Dimensions...
Страница 95: ...Camera Dimensions MIKROTRON GmbH D 2 MC1186 and 1187 Rear View...
Страница 96: ...Camera Dimensions MIKROTRON GmbH D 3 Side Views There are three side views available Side View without adapter...