Custom Features
4CXP Camera
MIKROTRON GmbH
page 59 of 70
InfoFieldFrameCounterEnable
This feature enables/disables the Frame Counter that can be added into the info field in the image.
Access
read/write
Type:
boolean
In:
Value
Description
0
info field disabled
1
info field is enabled
Out:
If this option is set a frame counter is superimposed into each captured frame or ROI.
The frame counter occupies 4 pixels in the upper left corner of each frame starting with
pixel number 0. After each activation, the counter starts with 0. When reaching the
maximal value or after each acquisition start command it will restart with 0.
Pixel Meaning
0
frame counter LSB part (counter bits 7...0). The values of pixel 0 and 1 are used to build a
consecutive running bit frame counter in little-endian notation. If the 24 bit counter overruns, it
restarts with 0.
1
frame counter, bits 15 … 8
2
frame counter, bits 16 … 23
3
ROI number
For cameras with the Multi-ROI feature the frame counter is inserted into each
ROI. This starts with 1 for ROI 1. Because a set of ROIs always belongs to one frame the frame
counter in each ROI is the same. For cameras without the Multi-ROI feature or if only one ROI is
defined, this value is always 1.
In 10 bit mode the bits 1 … 0 in each pixel will be set to 0.
Remark:
Implemented as 'Guru' feature.