CCR1016-12G
Safety Warnings
Before you work on any equipment, be aware of the hazards involved with electrical circuitry, and be familiar with standard practices for preventing
accidents.
Ultimate disposal of this product should be handled according to all national laws and regulations.
The Installation of the equipment must comply with local and national electrical codes.
This unit is intended to be installed in the rackmount. Please read the mounting instructions carefully before beginning installation. Failure to use the
correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system.
This product is intended to be installed indoors. Keep this product away from water, fire, humidity or hot environments.
Use only the power supply and accessories approved by the manufacturer, and which can be found in the original packaging of this product.
Read the installation instructions before connecting the system to the power source.
We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your
own risk!
In the case of device failure, please disconnect it from power. The fastest way to do so is by unplugging the power plug from the power outlet.
It is the customer's responsibility to follow local country regulations, including operation within legal frequency channels, output power, cabling
requirements, and Dynamic Frequency Selection (DFS) requirements. All Mikrotik devices must be professionally installed.
First use
The device comes preinstalled with RouterOS and is ready to use. The device is compatible with RouterOS v6.46 and newer, if your device comes
preinstalled with an earlier version, please upgrade before using it.
The Ethernet ports 1 has a default IP address for connecting: 192.168.88.1 username is admin and there is no password.
Please connect with your web browser to this IP address and choose Webfig to configure it.
The device doesn't have any other configuration applied by default, please connect to it, and set up WAN IP addresses, user password, firewall, etc.
Detailed info on how to upgrade the device
;
See this page for connection and configuration guides:
Powering
The device accepts powering through an IEC C14 standard connector and supports both 110/220 V. Two PSU for redundancy, each 100 - 240 V ~1.5 A, 50
/60 Hz.
Maximum power consumption 42 W.
Extension Slots and Ports
Twelve 10/100/1000 Mbit/s Gigabit Ethernet with Auto-MDI/X;
Integrated memory 2 GB;
micro-USB port type AB;
RS232 serial console port, The serial port is set by default to 115200bit/s, 8 data bits, 1 stop bit, no parity.
The Ether12 port accepts Etherboot/Netinstall for reinstalling RouterOS.