![Mikasa Sangyo Mvh-306 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/mikasa-sangyo/mvh-306/mvh-306_service-manual_1793910005.webp)
4. RULES FOR CONDUCTING SERVICE WORK
1. In order to avoid deficient reassembly, know normal status of installation before removing or
disassembling any part. Level check or replacement of vibrator oil should be carried out on level
ground.
2. Each time disassembly is made involving oil seal, gasket, packing, o-ring, lock washer or the like, be sure
to replace them with new ones.
3. Mating surfaces of vibrator case and compaction plate should be sealed with liquid gasket (Clean and
de-grease the mating surfaces thoroughly).
NOTE:
All the screw in use with this machine are right handed.
Table of Tightening Torque (kgf-cm)
Table 2
Screw diameter
Material
6mm
8mm
10mm
12mm
14mm
16mm
18mm
20mm
4T(SS41)
70
150
300
500
750
1,100
1,400
2,000
6-8T(S45C)
100
250
500
800
1,300
2,000
2,700
3,800
11T(SCM3)
150
400
800
1,200
2,000
2,900
4,200
5,600
In case counter
part is made from
aluminum
100
300
~
350
650
~
700
※
For indication in SI Unit (International Unit System), use the conversion of 1kgf-cm=9.80665N-cm
5. Disassembly work should be conducted where it is free from dust.
6. Where bonding agent such as Loctite has been in use and screw is hard to loosen, heat it with torch lamp
or the like. Such heated bolt must be replaced with new one, which is of high-tension type as specified.
7. Use proper tool in proper manner.
8. Remove (-) battery terminal first before disassembling and connect (-) battery terminal lastly.
Hydraulic hose tightening torque: Screw size 1/4 380kgf-cm
4
4. Clean the screw before coating with Loctite. For tightening bolts and nuts, use the specified standard
torque and bonding agent (Loctite or the like). For such bolts and nuts that are not specified, see Table
of Tightening Torque.