Usage of MIKrovent
®
Office
60
/ Professional
120
MIKrovent
®
Office
60
/ Professional
120
is intended for use from -
25° to 50°C outdoor
temperature. If the outdoor temperature is around 5°C, MIKrovent will work with interruptions
to prevent the condensation from freezing, resulting from its operation in the heat exchanger.
OUTDOOR AIR INLET
MIKrovent
®
Office
60
/ Professional
120
has special air nozzles on each side, allowing you to adjust
the air flow direction. The air flow is routed by rotating the nozzle for
180°. The longest range
-
the breakthrough of fresh air into the room - is achieved if you turn the two nozzles
to one another (as in the figure on the right).
Modes of operation
The device has 4 modes of operation:
MANUAL M
is a way to adjust the device to your own needs. The user himself adjusts the
amount of air through the device between 20 and 60 m3/h for MIKrovent Office
60
, and between
60 to 120 m3/h for MIKrovent Professional
120
. The user can choose between 5 levels of
operation, with 1 being the less, and 5 being the most intensive level of operation of the device.
AUTO A
is a way to use MIKrovent when we want the device to operate automatically, or
when we do not use ventilated place for a longer time. The device regulates the amount of
incoming and outgoing air according to the relative humidity and temperature in the room (if
the device has a built-in CO
2
, VOC or radon sensor, it is also regulated according to these
sensors). By increasing the amount of moisture and CO2 concentration, the operating power of
the device increases. Thanks to its own electronics protocol, the device will automatically adjust
its optimum performance according to the detected amount of temperature, humidity and CO
2
,
and ppm particles.
OUT
The device only pumps the air from the room. This method is used when we want to get
rid of bad air in the room quickly. In this mode, 5 levels of device operation are available. This
method is not recommended when using an open fire such as, for example, fireplace. Due to
vacuum in the room, harmful gases (CO2
etc…)
can escape from the fireplace. When air is
discharged, incomplete combustion and formation of carbon monoxide, which is fatal, may
occur.
IN
The device only supplies outside air to the room. Usually it is used for the natural cooling of
the rooms in the summer time, because with this way at night we bring a lot of fresh and cold
air. In the case when used in the room of a furnace or a fireplace, due to overpressure the
combustion air intake increases and thus improves the combustion in these devices. In this
mode, we have 5 levels of operation of the device, where the level 1 is also at least, and the 5th
degree is the most intensive level of operation of the device.