Too long time of refilling the water in brine 

tank 

Decrease the time of refilling the water in brine tank  

(unscrew the back side of steering valve) 

 

Leakage between the brine valve (air check) 

and the steering valve 

 

 

Check the connections between the brine valve (air check) 

and steering valve. Remove the hose connecting the steering 

valve from the brine valve and check if valve sucks the brine 

during the Brine Slow Rinse cycle 

Power failure during refilling water in the 

brine tank 

Check power supply 

Improperly connected softener 

Check the softener connections. IN 

 raw water inlet, OUT 

 

treated water outlet (see picture 2 page 7) 

Resin tank leakage 

Check the tank for leaks 

Clogged restrictor DLFC 

Clean the DLFC restrictor  

Water from the sewage system goes back and 

pours through the overflow  (on the side of 

the softener) to the brine tank 

Provide drain for overflow below the overflow elbow and 

the air gap between the drain pipe and the drain hose (see 

picture 1 page 6)  

Leakage from the connections (not tightened 

hoses for raw supplying water and treated 

water) 

Check the connections (inlet and outlet) for leaks 

11. The device does 

not draw brine 

Blocked or damaged injector 

Clean or replace the injector 

Leakage between the brine valve (air check) 

and the steering valve 

 

 

Check the connections between the brine valve (air check) 

and steering valve. Remove the hose connecting the steering 

valve from the brine valve and check if valve sucks the brine 

during the Brine Slow Rinse cycle  

Too low pressure in the water mains 

Increase water pressure at the inlet to the water softener to a 

minimum of 2,0 bar. 

Blocked hose or a brine valve (air chek) 

supplying brine to the driver 

Check a brine hose and remove any lock impeding the flow 

Cracked ball in the brine valve (air check) 

Replace the brine valve (air check) 

The drain is clogged. 

-Check the drain hose. If it is bent, collapsed broken or 

clogged, remove the hose from the drain pipe check if 

nothing is blocking it. Clean the drainage, if necessary, 

replace the hose  

- Make sure nothing is blocking the sewage pipe, clean the 

drainage 

Lack of water in the brine tank  

See problem 12 

„ S        V              f             k w    

w    ”

 

Содержание Maxi Elegant B65

Страница 1: ...BEDIENUNGSANLEITUNG englisch Wasserenth rter Maxi Elegant B65 KBS Gastrotechnik GmbH Johannes Kepler Str 14 55129 Mainz www kbs gastrotechnik de Stand November 2018...

Страница 2: ...C WATER SOFTENER STATION Maxi Elegant B65 Installer Stamp Date of Installation Serial Number Please read the operating manual before startup The manufacturer is not responsible for malfunctions caused...

Страница 3: ...ow it works 4 Standards provisions and statutory regulations 4 1 Description of the device 4 1 1 System structure 4 1 2 Technical description 4 1 3 Control function 6 2 Preparation for installation 6...

Страница 4: ...aning agents 13 The proper name and serial number of the device must be provided with any enquiries and ordering of spare parts Only then an effective and quick reply or order implementation is ensure...

Страница 5: ...e must comply with the requirements of the utility water use regulation 2 Parts that are in contact with treated water must be made of material resistant to treated water 3 In the room for the water t...

Страница 6: ...11 8182 15 0 21 6 214 3 12 7500 16 3 23 4 232 2 13 6923 17 5 25 2 250 0 14 6429 18 8 27 0 267 9 15 6000 20 0 28 8 285 8 16 5625 21 3 30 6 303 6 17 5294 22 5 32 4 321 5 18 5000 23 8 34 2 339 3 19 4737...

Страница 7: ...s side 1 Utility water supply pipe cold 3 4 w ff valve 2 Drainage sewer at a max height of 100 mm connection DN 50 3 Electric socket 230 V 50 Hz 16 A 4 Floor drainage must be in the room 5 Sediment f...

Страница 8: ...5 liters of water using buckets Check and tighten all fittings connecting the device Connect to electric Power socket The device is factory adjusted The fine tuning is done by the user on site Before...

Страница 9: ...midday e g 9a 9 00 AM p afternoon hours midday to midnight e g 9p 21 00 PM 2 Regeneration frequency Days of regeneration are set on the 12 day disk 4 Red arrow indicate the current day 5 To set regen...

Страница 10: ...regeneration process To manually initiate the regeneration process the user has to turn the knob 7 clockwise until REGEN is shown in the gap The knob 7 will turn and when the regeneration process is...

Страница 11: ...the brine tank Decrease the time of refilling the water in brine tank unscrew the back side of steering valve Power failure during the filling of the brine tank Check power supply 2 Water is pouring...

Страница 12: ...ers of hot water and mix to dissolve in Pour the brine into the brine tank and manually start the regeneration If water after regeneration is still hard replace the resin Refill the salt in the brine...

Страница 13: ...f k w w Open bypass Close bypass Lack of power during regeneration Provide the electric power supply during regeneration Lack of water during regeneration or not enough water during regeneration Prov...

Страница 14: ...tween the drain pipe and the drain hose see picture 1 page 6 Leakage from the connections not tightened hoses for raw supplying water and treated water Check the connections inlet and outlet for leaks...

Страница 15: ...alve and check the distribution pipe central pipe the upper basket lower basket if necessary replace Damaged upper basket lower basket or distributor Replace upper basket lower basket or distributor 1...

Страница 16: ...valve Water pressure is to high which result in valve doesn Reduce water pressure 20 Water softener efficiency decreased after few months Or years Frequent absence of salt or too little salt in the b...

Страница 17: ...il export mijar eu www mijar eu Product card Maxi Elegant B65 PRODUCT CARD C Date of installation Tested water hardneess Estimated efficiency days between regeneration Date Salt tablets verified suppl...

Отзывы: