background image

 

- 10 - 

Turn the burners on about 15-20 minutes before broiling for preheating, 

according to the cooking requirement to adjust the flame size. 

Notice: When first preheating, the furnace will smoke above. This is 

caused by protective lipids on the grates and other parts are heated, it is 
normal, and it will be eliminated after the power up to the maximum for burning 
an hour. 

 

8.5、Exchange main fire nozzle to switch gas source 

Remove control panel, cooking grates, the pilot light head, and burner, 

remove main fire nozzle with proper open spanner, exchange nozzle of another 
gas source, then screw it. Reinstall burner, the pilot light head, cooking 
grates and control panel in proper order.  

 

Caution: Each main fire orifice of the burner has been installed before 

delivery, normal use without adjustment but only switching gas. Adjust only 
by authorized and licensed technicians. When you converse the gas source, 
exchange the corresponding pressure maintaining valve which installed on air 
intake. See 2 in P17. 

 

8.6、Adjust air input 

Remove control panel, unscrew damper solid screw(Fig.6), revolve damper 

left to right (Fig.7), meanwhile, observe flame, to adjust an appropriate 
opening degree. Then screw damper solid screw, make sure the equipment will 
not get loose in the process of moving and translation. Reinstall control 
panel. 

 

Caution: Each burner damper has been adjusted before delivery (once air 

input), normal use without adjustment but only switching gas. Adjust only 
by authorized and licensed technicians. 

  

  

 

          Fig.5                    Fig.6                  Fig.7 
 

9. Cleaning and Maintenance 

 

Do not use any abrasive or flammable detergent to wipe; 

 

Do not hose down, immerse or pressure wash any part of the cooker, 

excluding the catch tray; 

 

Do not use abrasive cleaning matters to wash, even not use corrosive 

Содержание C-HP-2-12-LP

Страница 1: ...ktops Operating Instructions Before you begin please read these instructions carefully to use this product correctly to make the product perform ideally and to avoid hazards Models C HP 2 12 NG LP C H...

Страница 2: ...anual in a safe place for convenient reference and operation This instruction manual is subject to any change without further notice and the manufacturer reserves the right of final interpretation The...

Страница 3: ...n 3 2 Brief Instruction 3 3 Manufacture s Authority and Responsibility 3 4 Parameter Specifications 4 5 Transport and Storage 6 6 Installation and Debugging 6 7 Safety Notices and Precautions 8 8 Oper...

Страница 4: ...struction The product is a series of gas char broilers in our company production which is novel designed reasonable structured convenient operated durable used and convenient maintained It s equipped...

Страница 5: ...4 4 Parameter Specifications 4 1 Outline Dimensions in C HP 2 12 NG LP C HP 4 24 NG LP...

Страница 6: ...of burners and control method Gas Species Intake tube pressure in W C Per BTU B T U h Total BTU B T U h Nozzle No C HP 2 12 NG LP 2 pieces Independent control Natural Gas 4 25 000 50 000 43 L P Gas 1...

Страница 7: ...acking and Installation Please dispose of all packaging materials and residues after unpacking Check the equipment If it is damaged please keep wrappers and receipts which must be signed by the carrie...

Страница 8: ...um gases Warning Use soap water or testing instrument to test whether piping joint leaks or not before using and forbid using an open flame to test After installing completely you should check gas sup...

Страница 9: ...ch During operation do not directly touch burners and cooking grates Turn off the equipment as repairing maintaining and cleaning If the equipment has any problems of equipment damage gas piping leaks...

Страница 10: ...light then the main fire burner is lighted by the pilot light The power of burner increases as revolving angel increases When knob reaches to burner is in the maximum power Fig 4 Fig 2 Fig 3 Fig 4 Ma...

Страница 11: ...ut adjustment but only switching gas Adjust only by authorized and licensed technicians When you converse the gas source exchange the corresponding pressure maintaining valve which installed on air in...

Страница 12: ...censed technicians The product is made of 90 metals and can not be discarded everywhere Deal with it in accordance with the local codes Instructions to clean appliance regularly with recommended clean...

Страница 13: ...rd a sound of fire 1 Insufficient gas pressure in pipe 1 Contact the local gas supply dept 2 Not match nozzle aperture with gas resources 2 Adjust nozzle diameter 3 Flow of connection pipe is not enou...

Страница 14: ...other companies our company has the right not to provide warranty service Order replacement parts from authorized representatives and after sale service agency Provide the model number serial number...

Страница 15: ...01140001 Kirsite knob 2 C HP 2 12 NG LP 4 C HP 4 24 NG LP 6 C HP 6 36 NG LP 5 21103001033 Control panel 1 605 185 C HP 2 12 NG LP 21103002027 905 185 C HP 4 24 NG LP 21103003021 1205 185 C HP 6 36 NG...

Страница 16: ...5 301060002 Needle type pressure joint screw arbor 1 M5 23 C HP 2 12 NG LP C HP 4 24 NG LP C HP 6 36 NG LP 16 301990001 Damper cover 2 C HP 2 12 NG LP 4 C HP 4 24 NG LP 6 C HP 6 36 NG LP 17 301081002...

Страница 17: ...1015 Burner back plate 1 607 76 71 C HP 2 12 NG LP 2 C HP 4 24 NG LP 3 C HP 6 36 NG LP 27 21203001001 Unit 1 310 700 37 C HP 2 12 NG LP 21203002001 610 700 37 C HP 4 24 NG LP 21203003001 910 700 37 C...

Страница 18: ...maintaining valve connects with air intake must be installed by authorized and licensed technicians to ensure interface tightness 2 Screw the hex nut Fig 9 before connect air intake ensure gas mark Fi...

Страница 19: ...vantages of good durability and low maintenance charge But to update some components and necessary maintenance can prolong life length of the products Contact the dealer for assistance In order to avo...

Отзывы: