Installation
*
I
N
S
T
A
L
L
A
T
I
O
N
*
84
Electrical connection
The washing machine is supplied with
an electrical connection cable with
moulded plug ready for connection to a
switched socket.
The socket must be easily accessible
after the washing machine has been in-
stalled. If that is not possible, ensure
that a suitable means of disconnection
is provided on the installation side for
each pole.
Risk of fire from overheating.
Connecting the washing machine to
a multi-socket plug adapter or to an
extension lead can overload the
cable.
Do not use an extension lead or
multi-socket plug adapter.
The electrical system must comply with
local and national safety regulations
(BS 7671 in the UK).
If the connection cable is damaged, it
must only be replaced with a specific
connection cable of the same type
(available from the Miele Customer Ser-
vice Department). For safety reasons,
such replacement may only be carried
out by a qualified technician or the
Miele Customer Service Department.
The data plate indicates the nominal
power consumption and the appropri-
ate fuse rating. Compare the specifica-
tions on the data plate with those of the
electricity supply and make sure that
they match.
If in any doubt, consult a qualified elec-
trician.
Do not connect the washing machine to
a stand-alone inverter such as those
used with an autonomous energy
source, e.g. solar power. When the
washing machine is switched on, power
surges could result in a safety switch-
off. This could damage the electronic
module.
Содержание WSG 663 Series
Страница 85: ...85 ...
Страница 105: ......
Страница 106: ......
Страница 108: ...M Nr 11 360 150 00 en GB WSG 663 Selection ...