Notes for the installer
Levelling
The machine must stand level to ensure
smooth operation.
The adjustable feet can compensate for an
uneven base.
Screw the foot or feet out until the ma-
chine stands level.
Hold the foot tight using a pipe wrench.
Tighten the counternut using a screw-
driver as indicated.
Connection to water supply
Connection must be made to the water supply
via a stopcock which conforms with local and
national regulations. This work must be car-
ried out by a suitably qualified and competent
person.
To ensure the machine is correctly connected
please observe the installation plan and the in-
stallation instructions supplied with the ma-
chine.
See the installation diagram supplied for in-
structions on connection to the water supply
and for drainage.
The inlet pressure hoses supplied with the
machine must be used for connection to the
water supply.
To ensure the hot water inlet hose (marked
90°C) lasts for many years it is advised not to
use it on a hot water connection supplying
water hotter than 70°C.
If replacing an inlet hose only use a hose able
to withstand a burst pressure of at least 70
bar and a temperature of 90°C. This also ap-
plies to all connection parts.
Miele “Original” spare parts are tested to this
standard.
A water pressure flow rate of at least 1 bar,
maximum 10 bar is essential to ensure the
smooth operation of this machine.
Water taken into the machine must not ex-
ceed a temperature of 70°C.
Connection to cold water only
-See the Installation Plan provided.
Drainage
- Machines with a Drain Pump
The machine drains via a drain pump with a
delivery head of max. 1 metre. The 1.5 m
long drain hose must not be kinked as this re-
stricts drainage. The swivel elbow at the end
of the hose can be turned or detached.
Drainage possibilities:
Direct into a sink: (for the drain pump ver-
sion). Hook the hose over the edge and
secure.
Make sure the water can flow away freely
to avoid flooding and to prevent water
from being sucked back into the machine.
Connected securely to a standpipe.
Connected securely to a plastic drain pipe
with a rubber nipple. There is no need for
a non-return valve.
Via a floor drain (gully).
- Machines with a Drain Valve
The machine empties through a motor control-
led drain valve. A DN 50 angle connector can
be used to make connection to an on-site
drainage system, (sink box with odour trap).
33