Electrical connection U.K.
All electrical work should be carried out
only by a suitably qualified and compe-
tent person, in strict accordance with
national and local safety regulations.
The appliance is supplied with a mains
cable with moulded plug for connection
to a 230-240V mains supply.
The volt-
age, rated load and fuse rating are
given on the data plate
. Please ensure
these match the household mains sup-
ply.
Connection should be made via a fused
plug and suitable switched socket
which is easily accessible after installa-
tion. For extra safety it is advisable to
install a residual current device (RCD),
with a trip current of 30 mA (in accor-
dance with DIN VDE 0664, VDE 0100,
section 739). Do not connect via an ex-
tension lead.
Ensure power is not supplied to the ap-
pliance while installation work is being
carried out.
Important
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow
= earth
Blue
= neutral
Brown
= live
Where it is necessary to change plugs,
if the colours of the wires in the mains
lead of this appliance do not corre-
spond with the coloured markings iden-
tifying the terminals of your plug, pro-
ceed as follows:
^
The wire which is coloured green and
yellow must be connected to the ter-
minal in the plug which is marked
with the letter E or by the earth sym-
bol
z
or coloured green, or green
and yellow.
^
The wire which is coloured blue must
be connected to the terminal in the
plug which is marked with the letter N
or coloured black.
^
The wire which is coloured brown
must be connected to the terminal in
the plug which is marked with the let-
ter L or coloured red.
WARNING: THIS APPLIANCE
MUST BE EARTHED