Miele T 8019 Ci Скачать руководство пользователя страница 7

Panel Information

Integrated Laundry
T8019Ci Decor Unit

These units come equipped with a full size white front panel.  These units are also designed to either accept a thin insert or
a custom front panel supplied by the custom cabinet maker.

Sizes are as follows:

Version 1 - Thin insert

Width:

23 1/4" for all machines

Thickness:

up to 1/8"

Height:

25" in all cases

With this version, a thin white frame will be exposed after
installation

Version 2 - Custom Front Panel

Width:

23 3/8" for all machines

Thickness:

up to 3/4"

Height:

Up to 25"

With this version, the existing front panel is removed and
replaced by the new custom panel

Miele

Decor

Laundry unit

Hinge Notches

In certain installations, notches will be required to
accomodate the hinges in the front panel.

Miele

Decor

Laundry

Control
Panel

To center lines

16 3/4"

Notch Pattern

For this installation, drill the following
pattern in the appropriate locations.

Note:

To insure access to customer servicable features,

a minimum 4" toe kick above finished floor (AFF)
is required.

3 7/8"

C

C

C

1 1/8"

7/8"

1/4" Ø

1/4" Ø

1"

1"

Drill all holes
to a 5/8" depth

1 3/8" Ø

NOTE: Drawing is not to scale.

SPECIFICATION SHEETS  08262011

Содержание T 8019 Ci

Страница 1: ...21 1 2 V E Notes All installations must be done in accordance with local codes See Cut out Dimensions sheet for undercounter or built in space requirements E V 208 240 Volt 30 Amp 5 foot molded plug power supply connects upper right rear NEMA 14 30 Configuration Venting location may be adjusted to lower right or left side or lower left rear see separate sheet Location Codes ...

Страница 2: ...8013C 2 23 1 2 33 3 8 34 1 8 22 1 2 3 3 4 4 1 2 21 1 2 CD D E Notes All installations must be done in accordance with local codes See Cut out Dimensions sheet for undercounter or built in space requirements E 208 240 Volt 30 Amp 5 foot molded plug power supply connects upper right rear NEMA 14 30 Configuration Location Codes ...

Страница 3: ...t T8019Ci CD 2 23 1 2 33 3 8 34 1 8 22 1 2 5 7 8 3 3 4 4 1 2 1 1 2 D E Notes All installations must be done in accordance with local codes See Cut out Dimensions sheet for undercounter or built in space requirements E 208 240 Volt 30 Amp 5 foot molded plug power supply connects upper right rear NEMA 14 30 Configuration Location Codes ...

Страница 4: ...er Electrical Connection Location C 32 3 8 35 1 4 Location Codes C Cutout for Electric and Vent Drain pass through Adjust according to duct or drain location Needed depth will vary by model number T8003 T8013C 24 minimum T8019Ci 25 minimum Typically requires removal of unit s lid Out of box unit height dimension without lid is 32 5 16 32 11 16 Notes ...

Страница 5: ... SPECIFICATION SHEETS 08262011 Product Dimensions Laundry Stand WTS410 White Only 22 11 Notes For use with both large and super capacity washers or tumble dryers All installations must be done in accordnace with local codes 23 3 8 ...

Страница 6: ...guration 208 240 Volt 30 Amp 5 foot molded plug power supply connects upper right rear NEMA 14 30 Configuration 5 foot separate flexible hot and cold water intake hoses connect upper left rear Location Codes Notes All installations must be done in accordance with local codes See Cut out Dimensions sheet for undercounter or built in space requirements Remove transport struts in rear of machine befo...

Страница 7: ...r all machines Thickness up to 3 4 Height Up to 25 With this version the existing front panel is removed and replaced by the new custom panel Miele Decor Laundry unit Hinge Notches In certain installations notches will be required to accomodate the hinges in the front panel Miele Decor Laundry Control Panel To center lines 16 3 4 Notch Pattern For this installation drill the following pattern in t...

Страница 8: ...uct 90 12 20 inches 1 1 4 feet Flexible duct 45 4 20 inches 1 1 4 feet Smooth duct 90 or 45 4 8 inches 1 1 4 feet Elbow 90 Sharp bend 8 1 4 feet Concertina bend 8 inch 2 3 4 feet Segmented bend 8 inch 2 feet Louvered wall or window vent 03780400 12 1 2 feet Wall vent kit with flap 00087184 5 feet Window vent kit with flap 00087185 5 feet Exhaust connection left 20 feet Exhaust connection right 33 ...

Страница 9: ... Dryer Example Combination Rear View Left Side View Right Side View Vent Locations Corresponding Total Height with lid 66 3 8 67 1 8 4 3 4 36 3 8 37 1 8 Stacking Kit Stacking Kit 36 3 8 37 1 8 3 7 8 4 3 4 Stacking Kit 36 3 8 37 1 8 ...

Отзывы: