Notes
Reprogramming possibilities
Q
Programme
alterations
Position of the
Programme
selector switch
Options
Notes
Enter
programmed
options here
Standard
TR
Bedd-
ing
Adjustable
Co
tto
n
s
Reversing time*
in the Cottons
Programmes 1 to 6
and Timed drying
programmes 10 & 11
A
1
1 minute and
27 seconds
25
secs
25
secs
20 seconds
to
2 minutes
*)Drum reverses to the left
and to the right in pro-
grammed timed intervals
Reversing off /
Pause interval
in Cottons
programmes 1 to 6
and Timed drying
programmes 10 & 11
2
3
seconds
10
secs
0 (Off)
or
2 to 10
seconds
Residual moisture/
Prog. selection with the
Selector switch
3
see chart
"Programmable
residual
moisture"
Call up the residual moisture
values to be changed with
the selector switch and alter
with the start button.
Fan and heating
in pause times
4
1
0
0
0 or 1
1 = On
0 = Off
Cooling down temperature
Vented air to
5
50
o
C
40 °C
30 to 60
o
C
Reversing time*
in the Minimum iron
programmes 7 to 9
6
1 minute
27 seconds
55
secs
20 seconds
to
2 minutes
M
in
imu
m i
ro
n
Reversing off/
Pause interval
in Minimum iron
programmes 7 to 9
B
7
3
seconds
0 (Off)
or
2 to 10
seconds
without heating
Programme 10
8
15
minutes
3 minutes
to
1 hour
with heating
followed by Cooling down
Programme 11
9
20
minutes
3
mins
3 minutes
to
3 hours
add to this cooling down
time to a cool temperature
of 50
o
C (Standard value).
Ti
m
e
d
dr
y
in
g
Additional display
during operation
C
0
0
2
0, 1 or 2
0 = Residual moisture
(temperature display for
5 secs, after the selector
button is pressed)
1 = temperature only
2 = residual moisture only
!
Programme position is not
occupied.
Programmable residual moisture values
Programme
T 6251 / T 6351
Options
T 6551 / T 6751
Options
Notes
Enter
programmed
options here
Standard
Adjustable
Standard
Adjustable
A
1
- 4 %
- 3 % or - 5 %
- 4 %
- 3 % or - 5 %
2
- 2 %
- 1 or 0%
- 2 %
- 1 or 0%
3
3 %
1 % or 5 %
3 %
1 % or 5 %
4
13 %
8 % or 16 %
16 %
8 % or 13 %
5
20 %
18 % or 22 %
22 %
18 % or 20 %
6
26 %
24 % or 30 %
30 %
24 % or 26 %
B
7
- 2 %
0 % or - 3 %
- 2 %
0 % or - 3 %
8
2 %
1 % or 4 %
2 %
1 % or 4 %
9
8 %
5 % or 10 %
8 %
5 % or 10 %
The stored residual moisture values for the individual programmes are shown in the additional display after the selector is
pressed. The sequence of the displayed residual moisture values for the programmes is as follows:
A
/
3
,
A
/
2
,
A
/
1
,
B
/
9
,
B
/
8
,
B
/
7
,
A
/
6
,
A
/
5
,
A
/
4
19
«M.-Nr.04989220/02 - GB - »