Problem solving guide
The “Anti-crease” indicator
lamp in the sequence indica-
tor display starts flashing.
Release the “On/Off” button and
then press it in again.
Press the“Start” button.
If the indicator lamp starts flashing
again, this indicates a fault in the ma-
chine. Please then contact your Miele
Dealer or the Miele Service Dept.
The drum door opens during
the drying cycle.
The machine has overheated. The tem-
perature limiter opens the drum door
and thus causes the machine to switch
off automatically.
Possible reasons for overheating:
The fluff filter in the door is clogged
up.
The vent duct is blocked.
The vent aperture (e.g. louvred win-
dow vent, wall vent) is blocked.
Before restarting the programme, pro-
ceed as follows:
Clean the affected part of the ma-
chine.
Press the “Start” button.
Should the drum door open again, this
must be due to a technical fault and
the Service Dept. should be contacted.
The interior drum lighting fails
to function.
The bulb may be defective.
Replace it as follows:
Switch off the machine or disconnect
from the mains supply.
Open the door.
Use a 19 mm spanner to unscrew
the plastic cover inside the drum
above the door (see illustration).
The light bulb must not exceed the
maximum wattage quoted on the
data plate and the plastic light cover.
Replace the bulb and the plastic
cover.
The cover must be fixed securely, as
otherwise moisture may seep in and
cause a short-circuit.
The temperature-resistant bulb should
only be ordered from your Miele Dealer
or the Service Dept.
16