Technical Information
27
S 500 & S 600 Canister Vacuums
Cause:
The bag change indicator is set to mixed dust, but the composition of the dirt
taken into the vacuum cleaner does not come under the category of mixed
dust.
Remedy:
Turn the adjustment screw on the bag change indicator counterclockwise.
(See Figure 020-2.) The indicator then reacts later.
Figure 020-2:
Turning the Adjustment Screw Counterclockwise
3.3
Accessory Compartment Lid Difficult to Close
Cause:
Lid catch is stiff.
Remedy:
1. Open the lid.
2. Apply a thin coating of Baysilone oil (mat. no. 1940430 or 2988840) to the
catch retaining hooks.
Note:
Use only silicone oil; other types of oil can damage plastic parts.
3.4
Accessory Compartment Lid Difficult to Open
Cause:
Lid catch tabs are too long.
Remedy:
1. Open the lid.
2. Pull out the lid catch upwards.
3. Shorten both tabs by approximately one tenth of an inch (2 millimeters)
with a suitable sharp knife; see Figure 020-3.
Содержание S 500 Series
Страница 1: ...TECHNICAL INFORMATION S 500 and S 600 Canister Vacuums 2011 Miele USA ...
Страница 17: ...Technical Information 17 S 500 S 600 Canister Vacuums 010 Casing Bottom ...
Страница 25: ...Technical Information 25 S 500 S 600 Canister Vacuums 020 Casing Top ...
Страница 42: ...Technical Information 42 S 500 S 600 Canister Vacuums 030 Operating Unit S 51x S 61x shown ...
Страница 58: ...Technical Information 58 S 500 S 600 Canister Vacuums 040 Motor ...
Страница 61: ...Technical Information 61 S 500 S 600 Canister Vacuums 050 Suction Hose ...
Страница 63: ...Technical Information 63 S 500 S 600 Canister Vacuums 055 Electro Suction Hose S 558 S 658 ...