en - Technical data
49
Voltage versions and electrical data
3N AC 400 V SI/SD
Supply voltage
3N AC 400 V
Frequency
50/60 Hz
Required fuse rating (on site)
16 A
Power rating
2,3 kW
Connection cable, min. cross-section
1,5 mm²
Plumbing
Cold water connection
Required flow pressure
100 - 1000 kPa (1 - 10 bar)
Maximum flow rate
31,5 l/min
Threaded union required (male thread, to be provided by customer in accordance with
DIN 44991, flat sealing)
3 x 3/4"
Length of water inlet hose supplied
3 x 1550 mm
Hot water connection
Maximum permissible hot water temperature
70 °C
Required flow pressure
100 - 1000 kPa (1 - 10 bar)
Maximum flow rate
16 l/min
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
1 x 3/4"
Length of water inlet hose supplied
1550 mm
Hot water connection (for variants without heating or with reduced heater rating)
Maximum permissible hot water temperature
90 °C
Required flow pressure
100 - 1000 kPa (1 - 10 bar)
Maximum flow rate
16 l/min
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
1 x 1"
Length of water inlet hose supplied
1550 mm
Hard water connection (optional)
Required flow pressure
100 - 1000 kPa (1 - 10 bar)
Maximum flow rate
32 l/min
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
2 x 3/4"
Length of water inlet hose supplied
2 x 1550 mm
Indirect steam heating
Heater rating (peak capacity)
27 kW
Threaded union (on site)
2 x
½
"
Steam solenoid valve, dirt filter and steam shut-off valve must be installed by the customer on site. Follow the installation instructions
for steam-heated machines.
Содержание PWM 916 SD
Страница 2: ...2 de 4 en 29 fr 53 es 77 ru 102 it 128 ...
Страница 22: ...de Aufstellung INSTALLATION 22 Standard Maßangaben in Millimeter Standfuß ...
Страница 23: ...de Aufstellung INSTALLATION 23 Sockel Maßangaben in Millimeter ...
Страница 46: ...en Installation INSTALLATION 46 Standard Dimensions in mm Machine foot ...
Страница 47: ...en Installation INSTALLATION 47 Plinth Dimensions in mm ...
Страница 70: ...fr Installation INSTALLATION 70 Par défaut Dimensions en millimètres Pied ...
Страница 71: ...fr Installation INSTALLATION 71 Socle Dimensions en millimètres ...
Страница 95: ...es Emplazamiento INSTALLATION 95 Estándar Medidas en milímetros Base de apoyo ...
Страница 96: ...es Emplazamiento INSTALLATION 96 Zócalo Medidas en milímetros ...
Страница 121: ...ru Установка INSTALLATION 121 Стандарт Размеры в мм Ножка ...
Страница 122: ...ru Установка INSTALLATION 122 Цоколь Размеры в мм ...
Страница 146: ...it Posizionamento INSTALLATION 146 Standard Misure in millimetri Piedino ...
Страница 147: ...it Posizionamento INSTALLATION 147 Base Misure in millimetri ...